Construction and use of a custom-made digital pressure threshold device in cats
A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure thr...
Saved in:
Main Authors: | Basiri, Bita, Chen, Hee Chong, Dehzangi, Arash |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2012
|
Online Access: | http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf http://psasir.upm.edu.my/id/eprint/32215/ |