Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system
Microwave heating is a novel solution for milk pasteurisation but the non-uniformity of thermal distribution is still a significant problem that hampers its application especially for milk pasteurisation. This paper reports on the isotherm heating of a coaxial slot antenna applicator with a microwav...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Published: |
Academic Press
2022
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85123898140&doi=10.1016%2fj.biosystemseng.2022.01.013&partnerID=40&md5=4668429d996e7fdb80ef6e43b91c2c03 http://eprints.utp.edu.my/28619/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.28619 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.286192022-03-07T08:16:01Z Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system Abdullah, S.N. You, K.Y. Chong, C.Y. El-Enshasy, H.A. Mohamed Ali, M.S. Zainol, N.A. Ismael, A.H. Khe, C.S. Microwave heating is a novel solution for milk pasteurisation but the non-uniformity of thermal distribution is still a significant problem that hampers its application especially for milk pasteurisation. This paper reports on the isotherm heating of a coaxial slot antenna applicator with a microwave signal generation using a fabricated mono-mode microwave system designed to improve the temperature uniformity of batch milk pasteurisation. In this paper, applicator simulation, design, characterisation, and fabrication are described in detail. The fabricated microwave pasteurisation system was implemented using a digitally controlled water-cooled magnetron with a waveguide circulator, a three-screw waveguide tuner, a water-based waveguide terminator, and a rectangular to coaxial adapter to channel the output. The impedance matching and power calibration routines of the fabricated microwave pasteurisation system are explained and analysed in detail. Three microwave powers, namely 100 W, 125 W and 150 W were used to test and characterise the pasteurisation performance of the system. For each microwave power the thermal profile and the temperature distribution of the 100 ml milk samples in a glass beaker were simulated and measured. The pasteurisation process was evaluated based on the aerobic plate count (APC) test. Results showed 90 improvement in the temperature uniformity as compared with an existing batch microwave pasteurisation method. The APC test showed pasteurisation efficiency was 99.999 and total microbial elimination occurred after 7 min, 6 min, and 5 min of heating using 100 W, 125 W, and 150 W power respectively. © 2022 IAgrE Academic Press 2022 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85123898140&doi=10.1016%2fj.biosystemseng.2022.01.013&partnerID=40&md5=4668429d996e7fdb80ef6e43b91c2c03 Abdullah, S.N. and You, K.Y. and Chong, C.Y. and El-Enshasy, H.A. and Mohamed Ali, M.S. and Zainol, N.A. and Ismael, A.H. and Khe, C.S. (2022) Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system. Biosystems Engineering, 215 . pp. 271-282. http://eprints.utp.edu.my/28619/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Microwave heating is a novel solution for milk pasteurisation but the non-uniformity of thermal distribution is still a significant problem that hampers its application especially for milk pasteurisation. This paper reports on the isotherm heating of a coaxial slot antenna applicator with a microwave signal generation using a fabricated mono-mode microwave system designed to improve the temperature uniformity of batch milk pasteurisation. In this paper, applicator simulation, design, characterisation, and fabrication are described in detail. The fabricated microwave pasteurisation system was implemented using a digitally controlled water-cooled magnetron with a waveguide circulator, a three-screw waveguide tuner, a water-based waveguide terminator, and a rectangular to coaxial adapter to channel the output. The impedance matching and power calibration routines of the fabricated microwave pasteurisation system are explained and analysed in detail. Three microwave powers, namely 100 W, 125 W and 150 W were used to test and characterise the pasteurisation performance of the system. For each microwave power the thermal profile and the temperature distribution of the 100 ml milk samples in a glass beaker were simulated and measured. The pasteurisation process was evaluated based on the aerobic plate count (APC) test. Results showed 90 improvement in the temperature uniformity as compared with an existing batch microwave pasteurisation method. The APC test showed pasteurisation efficiency was 99.999 and total microbial elimination occurred after 7 min, 6 min, and 5 min of heating using 100 W, 125 W, and 150 W power respectively. © 2022 IAgrE |
format |
Article |
author |
Abdullah, S.N. You, K.Y. Chong, C.Y. El-Enshasy, H.A. Mohamed Ali, M.S. Zainol, N.A. Ismael, A.H. Khe, C.S. |
spellingShingle |
Abdullah, S.N. You, K.Y. Chong, C.Y. El-Enshasy, H.A. Mohamed Ali, M.S. Zainol, N.A. Ismael, A.H. Khe, C.S. Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
author_facet |
Abdullah, S.N. You, K.Y. Chong, C.Y. El-Enshasy, H.A. Mohamed Ali, M.S. Zainol, N.A. Ismael, A.H. Khe, C.S. |
author_sort |
Abdullah, S.N. |
title |
Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
title_short |
Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
title_full |
Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
title_fullStr |
Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
title_full_unstemmed |
Optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
title_sort |
optimisation of heating uniformity for milk pasteurisation using microwave coaxial slot applicator system |
publisher |
Academic Press |
publishDate |
2022 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85123898140&doi=10.1016%2fj.biosystemseng.2022.01.013&partnerID=40&md5=4668429d996e7fdb80ef6e43b91c2c03 http://eprints.utp.edu.my/28619/ |
_version_ |
1738656865571569664 |
score |
13.211869 |