Dielectrics for non-contact ECG bioelectrodes: a review

Sensing of bioelectrical potentials using a non-contact method remains promising for the long-term recording of heart biopotential signals. Recording electrocardiogram (ECG) in non-contact mode incorporates dielectric materials into capacitive bioelectrodes. Dielectrics have a strong influence on no...

全面介紹

Saved in:
書目詳細資料
Main Authors: Umar, Alhassan Haruna, Othman, Mohd. Afzan, Che Harun, Fauzan Khairi, Yusof, Yusmeeraz
格式: Article
出版: Institute of Electrical and Electronics Engineers Inc. 2021
主題:
在線閱讀:http://eprints.utm.my/id/eprint/94110/
http://dx.doi.org/10.1109/JSEN.2021.3092233
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.utm.94110
record_format eprints
spelling my.utm.941102022-02-28T13:32:06Z http://eprints.utm.my/id/eprint/94110/ Dielectrics for non-contact ECG bioelectrodes: a review Umar, Alhassan Haruna Othman, Mohd. Afzan Che Harun, Fauzan Khairi Yusof, Yusmeeraz TK Electrical engineering. Electronics Nuclear engineering Sensing of bioelectrical potentials using a non-contact method remains promising for the long-term recording of heart biopotential signals. Recording electrocardiogram (ECG) in non-contact mode incorporates dielectric materials into capacitive bioelectrodes. Dielectrics have a strong influence on non-contact bioelectrodes because the coupling capacitance relies primarily on the dielectric properties of the material. This review seeks to present an evaluation of relevant literature concerning various dielectrics that have been documented. It examines the extent of existing constraints in biosensing performance, biocompatibility, bioelectrode ergonomics, skin contact impedance and biosignal processing, and how they affect capacitive ECG measurement. It is also discussed that the performance of bioelectrodes is determined by materials' dielectric properties, making the choice of materials an essential factor in non-contact ECG recording applications. Finally, suggestions to enable the development of non-contact bioelectrodes with improved performance were highlighted. Institute of Electrical and Electronics Engineers Inc. 2021-09-01 Article PeerReviewed Umar, Alhassan Haruna and Othman, Mohd. Afzan and Che Harun, Fauzan Khairi and Yusof, Yusmeeraz (2021) Dielectrics for non-contact ECG bioelectrodes: a review. IEEE Sensors Journal, 21 (17). pp. 18353-18367. ISSN 1530-437X http://dx.doi.org/10.1109/JSEN.2021.3092233 DOI:10.1109/JSEN.2021.3092233
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Umar, Alhassan Haruna
Othman, Mohd. Afzan
Che Harun, Fauzan Khairi
Yusof, Yusmeeraz
Dielectrics for non-contact ECG bioelectrodes: a review
description Sensing of bioelectrical potentials using a non-contact method remains promising for the long-term recording of heart biopotential signals. Recording electrocardiogram (ECG) in non-contact mode incorporates dielectric materials into capacitive bioelectrodes. Dielectrics have a strong influence on non-contact bioelectrodes because the coupling capacitance relies primarily on the dielectric properties of the material. This review seeks to present an evaluation of relevant literature concerning various dielectrics that have been documented. It examines the extent of existing constraints in biosensing performance, biocompatibility, bioelectrode ergonomics, skin contact impedance and biosignal processing, and how they affect capacitive ECG measurement. It is also discussed that the performance of bioelectrodes is determined by materials' dielectric properties, making the choice of materials an essential factor in non-contact ECG recording applications. Finally, suggestions to enable the development of non-contact bioelectrodes with improved performance were highlighted.
format Article
author Umar, Alhassan Haruna
Othman, Mohd. Afzan
Che Harun, Fauzan Khairi
Yusof, Yusmeeraz
author_facet Umar, Alhassan Haruna
Othman, Mohd. Afzan
Che Harun, Fauzan Khairi
Yusof, Yusmeeraz
author_sort Umar, Alhassan Haruna
title Dielectrics for non-contact ECG bioelectrodes: a review
title_short Dielectrics for non-contact ECG bioelectrodes: a review
title_full Dielectrics for non-contact ECG bioelectrodes: a review
title_fullStr Dielectrics for non-contact ECG bioelectrodes: a review
title_full_unstemmed Dielectrics for non-contact ECG bioelectrodes: a review
title_sort dielectrics for non-contact ecg bioelectrodes: a review
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2021
url http://eprints.utm.my/id/eprint/94110/
http://dx.doi.org/10.1109/JSEN.2021.3092233
_version_ 1726791482551042048
score 13.251813