Finite element analysis of single cell stiffness measurements using PZT- integrated buckling nanoneedles
This paper proposes a new technique for real-time single cell stiffness measurement using lead zirconate titanate (PZT)-integrated buckling nanoneedles. The PZT and the buckling part of the nanoneedle have been modelled and validated using the ABAQUS software. The two parts are integrated together t...
Saved in:
Main Authors: | Alsadat Rad, Maryam, Tijjani, Auwal Shehu, Ahmad, Mohd Ridzuan, Muhammad Auwal, Shehu |
---|---|
Format: | Article |
Published: |
MDPI AG
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/66475/ http://dx.doi.org/10.3390/s17010014 |