Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor

The global electricity consumption demand grows at 2.1% per year from 2018 to 2040. Historically, the growth of Malaysia demand from 2015 to 2020 is 16,822MW to 18,808MW, or at 2.3% annually. Nowadays, people are more concerned about energy efficiency and conservation in buildings. The government ne...

Full description

Saved in:
Bibliographic Details
Main Author: Tuan Sembak, Syed Mohd. Aizuddin
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101761/1/SyedMohd.AizuddinMSChE2022.pdf.pdf
http://eprints.utm.my/id/eprint/101761/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:152369
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.101761
record_format eprints
spelling my.utm.1017612023-07-09T02:07:44Z http://eprints.utm.my/id/eprint/101761/ Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor Tuan Sembak, Syed Mohd. Aizuddin TP Chemical technology The global electricity consumption demand grows at 2.1% per year from 2018 to 2040. Historically, the growth of Malaysia demand from 2015 to 2020 is 16,822MW to 18,808MW, or at 2.3% annually. Nowadays, people are more concerned about energy efficiency and conservation in buildings. The government needs to ensure that energy is used at high efficiency and reduce waste. Since the commencement of operations, Institut Latihan Perindustrian (ILP) Tangkak has never conducted an energy audit. At present, energy audit is one of the effective approaches to identify efficient energy usages and cost saving. The purpose of this research is to conduct an energy audit in terms of study on the power and illuminance level for lighting, propose energy efficiency strategy of lighting system and to evaluate the proposed strategy in terms of techno-economic performance. This research presents the study of energy audit that will be conduct to analyze the lighting energy consumption pattern in library building at ILP Tangkak. Preliminary audit which involves a brief review of utility and building operation, observation and a walkthrough energy audit is performed as an input data for the baseline data. Real time data such as power rating, illuminance level and usage time will be collected. Existing lighting system which is T8 fluorescent tubes considered to examine the performance of the alternative efficient in terms of illuminance performance and energy performance of the proposed T8 and T5 Light Emitting Diode (LED) retrofit. Retrofitting of lighting on Library using DIALux software will be use to simulate in accordance to the MS1525 standard. Economic analysis including Payback Period (PP), Life Cycle Cost (LCC) and Annual Life Cycle Cost (ALCC) are indicators of economic performance that will be used. Energy Saving using T5 LED saves 11.5% more than T8 LED. The T8 LED technology shows lower PP and LCC value compared to T5. According to the ALCC, T5 LED technology shows lower value compared to T8 LED technology. 2022 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/101761/1/SyedMohd.AizuddinMSChE2022.pdf.pdf Tuan Sembak, Syed Mohd. Aizuddin (2022) Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor. Masters thesis, Universiti Teknologi Malaysia. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:152369
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Tuan Sembak, Syed Mohd. Aizuddin
Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
description The global electricity consumption demand grows at 2.1% per year from 2018 to 2040. Historically, the growth of Malaysia demand from 2015 to 2020 is 16,822MW to 18,808MW, or at 2.3% annually. Nowadays, people are more concerned about energy efficiency and conservation in buildings. The government needs to ensure that energy is used at high efficiency and reduce waste. Since the commencement of operations, Institut Latihan Perindustrian (ILP) Tangkak has never conducted an energy audit. At present, energy audit is one of the effective approaches to identify efficient energy usages and cost saving. The purpose of this research is to conduct an energy audit in terms of study on the power and illuminance level for lighting, propose energy efficiency strategy of lighting system and to evaluate the proposed strategy in terms of techno-economic performance. This research presents the study of energy audit that will be conduct to analyze the lighting energy consumption pattern in library building at ILP Tangkak. Preliminary audit which involves a brief review of utility and building operation, observation and a walkthrough energy audit is performed as an input data for the baseline data. Real time data such as power rating, illuminance level and usage time will be collected. Existing lighting system which is T8 fluorescent tubes considered to examine the performance of the alternative efficient in terms of illuminance performance and energy performance of the proposed T8 and T5 Light Emitting Diode (LED) retrofit. Retrofitting of lighting on Library using DIALux software will be use to simulate in accordance to the MS1525 standard. Economic analysis including Payback Period (PP), Life Cycle Cost (LCC) and Annual Life Cycle Cost (ALCC) are indicators of economic performance that will be used. Energy Saving using T5 LED saves 11.5% more than T8 LED. The T8 LED technology shows lower PP and LCC value compared to T5. According to the ALCC, T5 LED technology shows lower value compared to T8 LED technology.
format Thesis
author Tuan Sembak, Syed Mohd. Aizuddin
author_facet Tuan Sembak, Syed Mohd. Aizuddin
author_sort Tuan Sembak, Syed Mohd. Aizuddin
title Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
title_short Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
title_full Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
title_fullStr Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
title_full_unstemmed Energy audit and retrofit of lighting system at Institut Latihan Perindustrian (ILP) Tangkak, Johor
title_sort energy audit and retrofit of lighting system at institut latihan perindustrian (ilp) tangkak, johor