The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System

It is well known that the EHA system is exposed to the disturbances,uncertainties,and parameter variations which are caused by the changes in operating conditions for instance,total moving mass,supply pressure,servo-valve gain,bulk modulus,leakage coefficient,and friction.These problems pose to a gr...

Full description

Saved in:
Bibliographic Details
Main Author: Rozaimi, Ghazali
Format: Article
Language:English
Published: Science and Engineering Research Support Society 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/20825/2/20160901_IJCA_Chong.pdf
http://eprints.utem.edu.my/id/eprint/20825/
http://www.sersc.org/journals/IJCA/vol9_no11/24.pdf
http//dx.doi.org/10.14257/ijca.2016.9.11.24
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.20825
record_format eprints
spelling my.utem.eprints.208252021-07-08T21:10:41Z http://eprints.utem.edu.my/id/eprint/20825/ The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System Rozaimi, Ghazali T Technology (General) TL Motor vehicles. Aeronautics. Astronautics It is well known that the EHA system is exposed to the disturbances,uncertainties,and parameter variations which are caused by the changes in operating conditions for instance,total moving mass,supply pressure,servo-valve gain,bulk modulus,leakage coefficient,and friction.These problems pose to a great challenge in modelling and controller development for an EHA system.Degradation of the desired performance can be imposed if an improper control strategy is utilized.This paper discusses the fundamental study on the significant effect that leads to degradation of EHA system performance due to variation in the system parameters.A nonlinear EHA system model is developed and implemented in the simulation studies in open-loop and closed-loop control configuration.The finding shows that the servovalve gain resulted the most influential parameters to the EHA system performance as compared to the total moving mass and supply pressure parameters.In order to overcome these issues,the utilized controller should be robust enough to overcome the entire operating range that against such disturbances,uncertainties,and parameter variations.Therefore,a nonlinear and the intelligent control approach may be necessary to be designed in order to overcome these difficulties. Science and Engineering Research Support Society 2016-09 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/20825/2/20160901_IJCA_Chong.pdf Rozaimi, Ghazali (2016) The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System. International Journal Of Control And Automation, 9 (1). pp. 283-294. ISSN - http://www.sersc.org/journals/IJCA/vol9_no11/24.pdf http//dx.doi.org/10.14257/ijca.2016.9.11.24
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic T Technology (General)
TL Motor vehicles. Aeronautics. Astronautics
spellingShingle T Technology (General)
TL Motor vehicles. Aeronautics. Astronautics
Rozaimi, Ghazali
The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
description It is well known that the EHA system is exposed to the disturbances,uncertainties,and parameter variations which are caused by the changes in operating conditions for instance,total moving mass,supply pressure,servo-valve gain,bulk modulus,leakage coefficient,and friction.These problems pose to a great challenge in modelling and controller development for an EHA system.Degradation of the desired performance can be imposed if an improper control strategy is utilized.This paper discusses the fundamental study on the significant effect that leads to degradation of EHA system performance due to variation in the system parameters.A nonlinear EHA system model is developed and implemented in the simulation studies in open-loop and closed-loop control configuration.The finding shows that the servovalve gain resulted the most influential parameters to the EHA system performance as compared to the total moving mass and supply pressure parameters.In order to overcome these issues,the utilized controller should be robust enough to overcome the entire operating range that against such disturbances,uncertainties,and parameter variations.Therefore,a nonlinear and the intelligent control approach may be necessary to be designed in order to overcome these difficulties.
format Article
author Rozaimi, Ghazali
author_facet Rozaimi, Ghazali
author_sort Rozaimi, Ghazali
title The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
title_short The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
title_full The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
title_fullStr The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
title_full_unstemmed The Effects Of Parameter Variation In Open-Loop And Closed-Loop Control Scheme For An Electro-Hydraulic Actuator System
title_sort effects of parameter variation in open-loop and closed-loop control scheme for an electro-hydraulic actuator system
publisher Science and Engineering Research Support Society
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/20825/2/20160901_IJCA_Chong.pdf
http://eprints.utem.edu.my/id/eprint/20825/
http://www.sersc.org/journals/IJCA/vol9_no11/24.pdf
http//dx.doi.org/10.14257/ijca.2016.9.11.24
_version_ 1705060036701585408