Design sensitive model reference controller with application to medical technology

The past two decades have seen the incorporation of robotics into medical applications. From a manufacturing perspective, robots have been used in pharmaceuticals, preparing medications. But on more novel levels, robots have been used in service roles, surgery, and prosthetics. The capability of hig...

Full description

Saved in:
Bibliographic Details
Main Authors: Bahrami, Rouhollah, Soltani, Samira, Rashidi Bod, Hossein, Jowkar, Somayeh, Sahamijoo, Amirzubir, Taghizadegan, Ali, Sulaiman, Nasri. B
Format: Article
Language:English
Published: Science & Engineering Research Support Society (SERSC) 2016
Online Access:http://psasir.upm.edu.my/id/eprint/55456/1/Design%20sensitive%20model%20reference%20controller%20with%20application%20to%20medical%20technology.pdf
http://psasir.upm.edu.my/id/eprint/55456/
http://www.sersc.org/journals/IJHIT/vol9_no7_2016/23.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.55456
record_format eprints
spelling my.upm.eprints.554562017-09-14T09:57:56Z http://psasir.upm.edu.my/id/eprint/55456/ Design sensitive model reference controller with application to medical technology Bahrami, Rouhollah Soltani, Samira Rashidi Bod, Hossein Jowkar, Somayeh Sahamijoo, Amirzubir Taghizadegan, Ali Sulaiman, Nasri. B The past two decades have seen the incorporation of robotics into medical applications. From a manufacturing perspective, robots have been used in pharmaceuticals, preparing medications. But on more novel levels, robots have been used in service roles, surgery, and prosthetics. The capability of high-precision operation in manufacturing settings gave the medical industry high hopes that robots could be used to assist in surgery. Not only are robots capable of much higher precision than a human, they are not susceptible to human factors, such as trembling and sneezing, that are undesirable in the surgery room. Another advantage to robots in medicine is the ability to perform surgery with very small incisions, which results in minimal scar tissue, and dramatically reduced recovery times. The popularity of these minimally invasive surgical (MIS) procedures has enabled the incorporation of robots in surgeries. In this paper, model reference computed torque controller is recommended for four degrees of freedom serial links robot manipulator, which modeled in SIMSCAPE. To design stable controller conventional computed torque controller is recommended. It is a nonlinear, stable, and reliable controller. The proposed approach effectively combines of design methods from nonlinear controller, and linear Proportional-Derivative (PD) control to improve the performance and stability. This paper has two important objectives: a) study on modeling of 4 degrees of freedom (DOF) based on Simscape software and b) design PD model reference computed torque controller to improve the sensitivity of surgical robot manipulator. Science & Engineering Research Support Society (SERSC) 2016 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55456/1/Design%20sensitive%20model%20reference%20controller%20with%20application%20to%20medical%20technology.pdf Bahrami, Rouhollah and Soltani, Samira and Rashidi Bod, Hossein and Jowkar, Somayeh and Sahamijoo, Amirzubir and Taghizadegan, Ali and Sulaiman, Nasri. B (2016) Design sensitive model reference controller with application to medical technology. International Journal of Hybrid Information Technology, 9 (7). pp. 249-268. ISSN 1738-9968 http://www.sersc.org/journals/IJHIT/vol9_no7_2016/23.pdf 10.14257/ijhit .2016 .9.7.23
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description The past two decades have seen the incorporation of robotics into medical applications. From a manufacturing perspective, robots have been used in pharmaceuticals, preparing medications. But on more novel levels, robots have been used in service roles, surgery, and prosthetics. The capability of high-precision operation in manufacturing settings gave the medical industry high hopes that robots could be used to assist in surgery. Not only are robots capable of much higher precision than a human, they are not susceptible to human factors, such as trembling and sneezing, that are undesirable in the surgery room. Another advantage to robots in medicine is the ability to perform surgery with very small incisions, which results in minimal scar tissue, and dramatically reduced recovery times. The popularity of these minimally invasive surgical (MIS) procedures has enabled the incorporation of robots in surgeries. In this paper, model reference computed torque controller is recommended for four degrees of freedom serial links robot manipulator, which modeled in SIMSCAPE. To design stable controller conventional computed torque controller is recommended. It is a nonlinear, stable, and reliable controller. The proposed approach effectively combines of design methods from nonlinear controller, and linear Proportional-Derivative (PD) control to improve the performance and stability. This paper has two important objectives: a) study on modeling of 4 degrees of freedom (DOF) based on Simscape software and b) design PD model reference computed torque controller to improve the sensitivity of surgical robot manipulator.
format Article
author Bahrami, Rouhollah
Soltani, Samira
Rashidi Bod, Hossein
Jowkar, Somayeh
Sahamijoo, Amirzubir
Taghizadegan, Ali
Sulaiman, Nasri. B
spellingShingle Bahrami, Rouhollah
Soltani, Samira
Rashidi Bod, Hossein
Jowkar, Somayeh
Sahamijoo, Amirzubir
Taghizadegan, Ali
Sulaiman, Nasri. B
Design sensitive model reference controller with application to medical technology
author_facet Bahrami, Rouhollah
Soltani, Samira
Rashidi Bod, Hossein
Jowkar, Somayeh
Sahamijoo, Amirzubir
Taghizadegan, Ali
Sulaiman, Nasri. B
author_sort Bahrami, Rouhollah
title Design sensitive model reference controller with application to medical technology
title_short Design sensitive model reference controller with application to medical technology
title_full Design sensitive model reference controller with application to medical technology
title_fullStr Design sensitive model reference controller with application to medical technology
title_full_unstemmed Design sensitive model reference controller with application to medical technology
title_sort design sensitive model reference controller with application to medical technology
publisher Science & Engineering Research Support Society (SERSC)
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/55456/1/Design%20sensitive%20model%20reference%20controller%20with%20application%20to%20medical%20technology.pdf
http://psasir.upm.edu.my/id/eprint/55456/
http://www.sersc.org/journals/IJHIT/vol9_no7_2016/23.pdf
_version_ 1643835900877078528
score 13.226497