Determination of spillway capacity of proposed bengoh dam

The aim of the study is to determine the spillway capacity of proposed Bengoh dam. The proposed Bengoh dam is located 43 km away from Kuching city. The purpose of the construction of Bengoh dam is to supply more raw water supply to Batu Kitang Water Treatment Plant due to increase in water demand...

Full description

Saved in:
Bibliographic Details
Main Author: John Gary, J.
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak, UNIMAS 2009
Subjects:
Online Access:http://ir.unimas.my/id/eprint/4532/1/DETERMINATION%20OF%20SPILLWAY%20CAPACITY%20OF%20PROPOSED%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/4532/8/DETERMINATION%20OF%20SPILLWAY%20...%28fulltext%29.pdf
http://ir.unimas.my/id/eprint/4532/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.4532
record_format eprints
spelling my.unimas.ir.45322023-07-03T04:31:09Z http://ir.unimas.my/id/eprint/4532/ Determination of spillway capacity of proposed bengoh dam John Gary, J. TA Engineering (General). Civil engineering (General) TC Hydraulic engineering. Ocean engineering The aim of the study is to determine the spillway capacity of proposed Bengoh dam. The proposed Bengoh dam is located 43 km away from Kuching city. The purpose of the construction of Bengoh dam is to supply more raw water supply to Batu Kitang Water Treatment Plant due to increase in water demand in Kuching area. The geography and hydrology location of Sg. Bengoh make it suitable to construct a dam in that location. The Bengoh dam’s spillway should be able to pass the peak outflow during the design flood in Sg. Bengoh. In this study, the determination of spillway capacity of proposed Bengoh dam is conducted by analyzing the design flood to produce the outflow hydrograph for the spillway. The determination of spillway capacity is very important in designing spillway structure. Sufficient design of spillway can avoid dam overtopping which may lead to destruction of the dam that can affect the environment and injury to human downstream of the dam. Universiti Malaysia Sarawak, UNIMAS 2009 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/4532/1/DETERMINATION%20OF%20SPILLWAY%20CAPACITY%20OF%20PROPOSED%20%2824pgs%29.pdf text en http://ir.unimas.my/id/eprint/4532/8/DETERMINATION%20OF%20SPILLWAY%20...%28fulltext%29.pdf John Gary, J. (2009) Determination of spillway capacity of proposed bengoh dam. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic TA Engineering (General). Civil engineering (General)
TC Hydraulic engineering. Ocean engineering
spellingShingle TA Engineering (General). Civil engineering (General)
TC Hydraulic engineering. Ocean engineering
John Gary, J.
Determination of spillway capacity of proposed bengoh dam
description The aim of the study is to determine the spillway capacity of proposed Bengoh dam. The proposed Bengoh dam is located 43 km away from Kuching city. The purpose of the construction of Bengoh dam is to supply more raw water supply to Batu Kitang Water Treatment Plant due to increase in water demand in Kuching area. The geography and hydrology location of Sg. Bengoh make it suitable to construct a dam in that location. The Bengoh dam’s spillway should be able to pass the peak outflow during the design flood in Sg. Bengoh. In this study, the determination of spillway capacity of proposed Bengoh dam is conducted by analyzing the design flood to produce the outflow hydrograph for the spillway. The determination of spillway capacity is very important in designing spillway structure. Sufficient design of spillway can avoid dam overtopping which may lead to destruction of the dam that can affect the environment and injury to human downstream of the dam.
format Final Year Project Report
author John Gary, J.
author_facet John Gary, J.
author_sort John Gary, J.
title Determination of spillway capacity of proposed bengoh dam
title_short Determination of spillway capacity of proposed bengoh dam
title_full Determination of spillway capacity of proposed bengoh dam
title_fullStr Determination of spillway capacity of proposed bengoh dam
title_full_unstemmed Determination of spillway capacity of proposed bengoh dam
title_sort determination of spillway capacity of proposed bengoh dam
publisher Universiti Malaysia Sarawak, UNIMAS
publishDate 2009
url http://ir.unimas.my/id/eprint/4532/1/DETERMINATION%20OF%20SPILLWAY%20CAPACITY%20OF%20PROPOSED%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/4532/8/DETERMINATION%20OF%20SPILLWAY%20...%28fulltext%29.pdf
http://ir.unimas.my/id/eprint/4532/
_version_ 1770555378954665984
score 13.211869