Langmuir probe measurement in a radio frequency inductively coupled argon plasma

A Langmuir probe diagnostic system is constructed to measure the plasma properties in a radio frequency (RF) inductively coupled Argon plasma. A passive compensation is incorporated into the Langmuir probe to provide the high impedance to the probe tip in the fundamental drive frequency of 13.56 MHz...

Full description

Saved in:
Bibliographic Details
Main Authors: Onga, C.L., Chin, O.H., Nisoab, Mudtorlep, Paosawatyanyangc, Boonchoat
Format: Article
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.um.edu.my/7712/1/Langmuir_probe_measurement_in_a_radio_frequency_inductively_coupled_argon_plasma.pdf
http://eprints.um.edu.my/7712/
Tags: Add Tag
No Tags, Be the first to tag this record!
Be the first to leave a comment!
You must be logged in first