Langmuir probe measurement in a radio frequency inductively coupled argon plasma

A Langmuir probe diagnostic system is constructed to measure the plasma properties in a radio frequency (RF) inductively coupled Argon plasma. A passive compensation is incorporated into the Langmuir probe to provide the high impedance to the probe tip in the fundamental drive frequency of 13.56 MHz...