Finger-actuated micropump of constant flow rate without backflow
This paper presents a finger-actuated micropump with a consistent flow rate and no backflow. The fluid dynamics in interstitial fluid (ISF) extraction microfluidics are studied through analytical, simulation, and experimental methods. Head losses, pressure drop, diodocity, hydrogel swelling, criteri...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Published: |
MDPI
2023
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/38322/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.38322 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.383222023-12-01T13:22:46Z http://eprints.um.edu.my/38322/ Finger-actuated micropump of constant flow rate without backflow Ahmad, NurFarrahain Nadia Nik Ghazali, Nik Nazri Rani, Ahmad Taufiq Abdul Othman, Mohammad Hafiz Kee, Chia Ching Jiwanti, Prastika Krisma Rodriguez-Gomez, Arturo Wong, Yew Hoong T Technology (General) TJ Mechanical engineering and machinery This paper presents a finger-actuated micropump with a consistent flow rate and no backflow. The fluid dynamics in interstitial fluid (ISF) extraction microfluidics are studied through analytical, simulation, and experimental methods. Head losses, pressure drop, diodocity, hydrogel swelling, criteria for hydrogel absorption, and consistency flow rate are examined in order to access microfluidic performance. In terms of consistency, the experimental result revealed that after 20 s of duty cycles with full deformation on the flexible diaphragm, the output pressure became uniform and the flow rate remained at nearly constant levels of 2.2 mu L/min. The flow rate discrepancy between the experimental and predicted flow rates is around 22%. In terms of diodicity, when the serpentine microchannel and hydrogel-assisted reservoir are added to the microfluidic system integration, the diodicity increases by 2% (Di = 1.48) and 34% (Di = 1.96), respectively, compared to when the Tesla integration (Di = 1.45) is used alone. A visual and experimentally weighted analysis finds no signs of backflow. These significant flow characteristics demonstrate their potential usage in many low-cost and portable microfluidic applications. MDPI 2023-04 Article PeerReviewed Ahmad, NurFarrahain Nadia and Nik Ghazali, Nik Nazri and Rani, Ahmad Taufiq Abdul and Othman, Mohammad Hafiz and Kee, Chia Ching and Jiwanti, Prastika Krisma and Rodriguez-Gomez, Arturo and Wong, Yew Hoong (2023) Finger-actuated micropump of constant flow rate without backflow. Micromachines, 14 (4). ISSN 2072-666X, DOI https://doi.org/10.3390/mi14040881 <https://doi.org/10.3390/mi14040881>. 10.3390/mi14040881 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
T Technology (General) TJ Mechanical engineering and machinery |
spellingShingle |
T Technology (General) TJ Mechanical engineering and machinery Ahmad, NurFarrahain Nadia Nik Ghazali, Nik Nazri Rani, Ahmad Taufiq Abdul Othman, Mohammad Hafiz Kee, Chia Ching Jiwanti, Prastika Krisma Rodriguez-Gomez, Arturo Wong, Yew Hoong Finger-actuated micropump of constant flow rate without backflow |
description |
This paper presents a finger-actuated micropump with a consistent flow rate and no backflow. The fluid dynamics in interstitial fluid (ISF) extraction microfluidics are studied through analytical, simulation, and experimental methods. Head losses, pressure drop, diodocity, hydrogel swelling, criteria for hydrogel absorption, and consistency flow rate are examined in order to access microfluidic performance. In terms of consistency, the experimental result revealed that after 20 s of duty cycles with full deformation on the flexible diaphragm, the output pressure became uniform and the flow rate remained at nearly constant levels of 2.2 mu L/min. The flow rate discrepancy between the experimental and predicted flow rates is around 22%. In terms of diodicity, when the serpentine microchannel and hydrogel-assisted reservoir are added to the microfluidic system integration, the diodicity increases by 2% (Di = 1.48) and 34% (Di = 1.96), respectively, compared to when the Tesla integration (Di = 1.45) is used alone. A visual and experimentally weighted analysis finds no signs of backflow. These significant flow characteristics demonstrate their potential usage in many low-cost and portable microfluidic applications. |
format |
Article |
author |
Ahmad, NurFarrahain Nadia Nik Ghazali, Nik Nazri Rani, Ahmad Taufiq Abdul Othman, Mohammad Hafiz Kee, Chia Ching Jiwanti, Prastika Krisma Rodriguez-Gomez, Arturo Wong, Yew Hoong |
author_facet |
Ahmad, NurFarrahain Nadia Nik Ghazali, Nik Nazri Rani, Ahmad Taufiq Abdul Othman, Mohammad Hafiz Kee, Chia Ching Jiwanti, Prastika Krisma Rodriguez-Gomez, Arturo Wong, Yew Hoong |
author_sort |
Ahmad, NurFarrahain Nadia |
title |
Finger-actuated micropump of constant flow rate without backflow |
title_short |
Finger-actuated micropump of constant flow rate without backflow |
title_full |
Finger-actuated micropump of constant flow rate without backflow |
title_fullStr |
Finger-actuated micropump of constant flow rate without backflow |
title_full_unstemmed |
Finger-actuated micropump of constant flow rate without backflow |
title_sort |
finger-actuated micropump of constant flow rate without backflow |
publisher |
MDPI |
publishDate |
2023 |
url |
http://eprints.um.edu.my/38322/ |
_version_ |
1784511839121440768 |
score |
13.211869 |