A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study
The telmisartan was determined in a rat plasma using developed and validated a reversed-phase high performance liquid chromatographic (HPLC). The pre-treatment of the plasma sample involving liquid-liquid extraction using ethanol as the extracting solvent. The HPLC method validation has been shown a...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
2021
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/35473/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108295714&doi=10.52711%2f0974-360X.2021.00379&partnerID=40&md5=034635993c3af6155b22906ec0c00b34 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.35473 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.354732023-10-09T08:05:52Z http://eprints.um.edu.my/35473/ A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study Al-Japairai, K.A.S. Chatterjee, B. Mahmood, Syed Almurisi, S.H. RS Pharmacy and materia medica The telmisartan was determined in a rat plasma using developed and validated a reversed-phase high performance liquid chromatographic (HPLC). The pre-treatment of the plasma sample involving liquid-liquid extraction using ethanol as the extracting solvent. The HPLC method validation has been shown a linear calibration curve over a plasma concentrations range of 0.7 to 10µg/mL with a correlation coefficient of 0.9979, the limit of detection and the limit of quantification were determined to be 0.025µg/ml and 0.07µg/ml, respectively. The precision and accuracy were in an acceptable limit. The pharmacokinetic parameters of telmisartan were adequately evaluated following a single oral dose (4mg/kg) in Sprague-Dawley rats. The results observed conclude that the developed bioanalytical HPLC method is appropriate and applicable as an analytical tool in the pharmacokinetic study of telmisartan. © RJPT All right reserved. 2021 Article PeerReviewed Al-Japairai, K.A.S. and Chatterjee, B. and Mahmood, Syed and Almurisi, S.H. (2021) A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study. Research Journal of Pharmacy and Technology, 14 (4). pp. 2139-2144. ISSN 0974-3618, DOI https://doi.org/10.52711/0974-360X.2021.00379 <https://doi.org/10.52711/0974-360X.2021.00379>. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108295714&doi=10.52711%2f0974-360X.2021.00379&partnerID=40&md5=034635993c3af6155b22906ec0c00b34 10.52711/0974-360X.2021.00379 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
RS Pharmacy and materia medica |
spellingShingle |
RS Pharmacy and materia medica Al-Japairai, K.A.S. Chatterjee, B. Mahmood, Syed Almurisi, S.H. A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
description |
The telmisartan was determined in a rat plasma using developed and validated a reversed-phase high performance liquid chromatographic (HPLC). The pre-treatment of the plasma sample involving liquid-liquid extraction using ethanol as the extracting solvent. The HPLC method validation has been shown a linear calibration curve over a plasma concentrations range of 0.7 to 10µg/mL with a correlation coefficient of 0.9979, the limit of detection and the limit of quantification were determined to be 0.025µg/ml and 0.07µg/ml, respectively. The precision and accuracy were in an acceptable limit. The pharmacokinetic parameters of telmisartan were adequately evaluated following a single oral dose (4mg/kg) in Sprague-Dawley rats. The results observed conclude that the developed bioanalytical HPLC method is appropriate and applicable as an analytical tool in the pharmacokinetic study of telmisartan. © RJPT All right reserved. |
format |
Article |
author |
Al-Japairai, K.A.S. Chatterjee, B. Mahmood, Syed Almurisi, S.H. |
author_facet |
Al-Japairai, K.A.S. Chatterjee, B. Mahmood, Syed Almurisi, S.H. |
author_sort |
Al-Japairai, K.A.S. |
title |
A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
title_short |
A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
title_full |
A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
title_fullStr |
A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
title_full_unstemmed |
A bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
title_sort |
bioanalytical method for quantification of telmisartan in rat plasma; development, validation and application to pharmacokinetic study |
publishDate |
2021 |
url |
http://eprints.um.edu.my/35473/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108295714&doi=10.52711%2f0974-360X.2021.00379&partnerID=40&md5=034635993c3af6155b22906ec0c00b34 |
_version_ |
1781704472600248320 |
score |
13.211869 |