Monitoring fracture of steel corroded reinforced concrete members under flexure by acoustic emission technique

Acoustic emission (AE) technique is used for monitoring and evaluating the influence of corrosion on the structural behaviour of steel reinforced concrete (RC) beams under three-point flexure test. In this study, steel corrosion was accelerated by electro-chemical method utilising a direct current (...

Full description

Saved in:
Bibliographic Details
Main Authors: Zaki, A., Chai, H.K., Behnia, A., Aggelis, D.G., Tan, J.Y., Ibrahim, Z.
Format: Article
Published: Elsevier 2017
Subjects:
Online Access:http://eprints.um.edu.my/18837/
http://dx.doi.org/10.1016/j.conbuildmat.2016.11.079
Tags: Add Tag