Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter
In this paper a compensating system using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network which will be able to mitigate harmonics, absorb or generate reactive power, and improve the power factor on supply side, is presented. Two control approaches based on...
Saved in:
Main Author: | |
---|---|
Format: | Conference or Workshop Item |
Published: |
2010
|
Subjects: | |
Online Access: | http://eprints.utp.edu.my/4648/1/Harmonic_Mitigation_in_Power_Factor_Correction.pdf http://eprints.utp.edu.my/4648/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.4648 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.46482017-01-19T08:23:41Z Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter Nallagownden, Perumal TK Electrical engineering. Electronics Nuclear engineering In this paper a compensating system using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network which will be able to mitigate harmonics, absorb or generate reactive power, and improve the power factor on supply side, is presented. Two control approaches based on p-q theory and load current detection using phase locked loop (PLL) are proposed. To validate the compensation performance of SAPF the distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results have proved and validated the performance of SAPF minimizing the total harmonics distortion (THD) and neutral current 2010-11-29 Conference or Workshop Item NonPeerReviewed application/pdf http://eprints.utp.edu.my/4648/1/Harmonic_Mitigation_in_Power_Factor_Correction.pdf Nallagownden, Perumal (2010) Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter. In: 2010 IEEE International Conference on Power and Energy (PECon 2010), , Nov 29 - 1 Dec 2010, Kuala Lumpur. http://eprints.utp.edu.my/4648/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Nallagownden, Perumal Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
description |
In this paper a compensating system using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network which will be able to mitigate harmonics, absorb or generate reactive power, and improve the power factor on supply side, is presented. Two control approaches based on p-q theory and load current detection using phase locked loop (PLL) are proposed. To validate the compensation performance of SAPF the distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results have proved and validated the performance of SAPF minimizing the total harmonics distortion (THD) and neutral current |
format |
Conference or Workshop Item |
author |
Nallagownden, Perumal |
author_facet |
Nallagownden, Perumal |
author_sort |
Nallagownden, Perumal |
title |
Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
title_short |
Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
title_full |
Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
title_fullStr |
Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
title_full_unstemmed |
Harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
title_sort |
harmonics mitigation and power factor correction with a modern three-phase four-leg shunt active power filter |
publishDate |
2010 |
url |
http://eprints.utp.edu.my/4648/1/Harmonic_Mitigation_in_Power_Factor_Correction.pdf http://eprints.utp.edu.my/4648/ |
_version_ |
1738655359625592832 |
score |
13.251813 |