Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section

An experimental loop set up used in this study is dedicated to model the wax deposition in oil and gas transportation. The flow behavior and the pressure drop throughout the test section were investigated in order to justify the usage of the system. The test section has an annular shape of 3 m lengt...

Full description

Saved in:
Bibliographic Details
Main Authors: Ibrahim, M.A., Al-Kayiem, Hussain H.
Format: Article
Published: PETRONAS 2009
Subjects:
Online Access:http://eprints.utp.edu.my/4209/1/prediction_of_pressure_drop_1_page_.pdf
http://eprints.utp.edu.my/4209/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.4209
record_format eprints
spelling my.utp.eprints.42092017-01-19T08:25:22Z Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section Ibrahim, M.A. Al-Kayiem, Hussain H. TJ Mechanical engineering and machinery TP Chemical technology An experimental loop set up used in this study is dedicated to model the wax deposition in oil and gas transportation. The flow behavior and the pressure drop throughout the test section were investigated in order to justify the usage of the system. The test section has an annular shape of 3 m length, 0.0422 m ID and .0801 m OD. Oil is re-circulated in the annular passage while a cold water-glycol mixture is re-circulated in the inner pipe and counter currently to the oil flow. The experiments were carried out at annulus Reynolds number range of 400 to 17000 with different flow conditions. It was noted that the calculated pressure drop values were considerably higher than the measured ones and the differences increase with the flow rate increments. The equivalent length method has been used as a correction technique to characterize the pressure drop in the test section. After applying the correction method, the analysis revealed that the test facility can yield a pressure drop prediction with an accuracy of 5%. KEYWORDS: Annular flow, Equivalent Length Method, Pressure drop characterization. PETRONAS 2009-06 Article PeerReviewed application/pdf http://eprints.utp.edu.my/4209/1/prediction_of_pressure_drop_1_page_.pdf Ibrahim, M.A. and Al-Kayiem, Hussain H. (2009) Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section. PETRONAS TECHNOLOGY JOURNAL, 2 (spe (2). pp. 46-52. ISSN KDN: PP 15855/07/2009(021898) http://eprints.utp.edu.my/4209/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
TP Chemical technology
spellingShingle TJ Mechanical engineering and machinery
TP Chemical technology
Ibrahim, M.A.
Al-Kayiem, Hussain H.
Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
description An experimental loop set up used in this study is dedicated to model the wax deposition in oil and gas transportation. The flow behavior and the pressure drop throughout the test section were investigated in order to justify the usage of the system. The test section has an annular shape of 3 m length, 0.0422 m ID and .0801 m OD. Oil is re-circulated in the annular passage while a cold water-glycol mixture is re-circulated in the inner pipe and counter currently to the oil flow. The experiments were carried out at annulus Reynolds number range of 400 to 17000 with different flow conditions. It was noted that the calculated pressure drop values were considerably higher than the measured ones and the differences increase with the flow rate increments. The equivalent length method has been used as a correction technique to characterize the pressure drop in the test section. After applying the correction method, the analysis revealed that the test facility can yield a pressure drop prediction with an accuracy of 5%. KEYWORDS: Annular flow, Equivalent Length Method, Pressure drop characterization.
format Article
author Ibrahim, M.A.
Al-Kayiem, Hussain H.
author_facet Ibrahim, M.A.
Al-Kayiem, Hussain H.
author_sort Ibrahim, M.A.
title Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
title_short Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
title_full Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
title_fullStr Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
title_full_unstemmed Prediction of Pressure Drop Correction to Suit Wax Deposition Modeling in Annular Test Section
title_sort prediction of pressure drop correction to suit wax deposition modeling in annular test section