Adaptive calibration of a capacitance tomography system for imaging water droplet distribution
A highly sensitive electrical capacitance tomography (ECT) system based on an HP4284 impedance analyser has been developed and used to quantify low concentration multi-phase flows in wet gas separation processes. The system hardware provides high accuracy (0.05%) and high resolution (10−17 F). The s...
保存先:
主要な著者: | Yang, W Q, Chondronasios, A, Nattrass, S, Nguyen, V T, Betting, M, Ismail, Idris, McCann, H |
---|---|
フォーマット: | 論文 |
出版事項: |
Elsevier
2004
|
主題: | |