Study of Void Fraction Measurement in a Two Phase Flow by Using Differential Pressure and Electrical Capacitance Tomography

This experimental study uses Electrical Capacitance Tomography (ECT) technique for measuring the void fraction in two phase bubble flow regime. Void fraction was measured by using differential pressure calculations in a vertical fluid column (ECT sensor) with inner diameter 4.93 cm and height 40.996...

Full description

Saved in:
Bibliographic Details
Main Authors: Shafquet, Areeba, Ismail, Idris, Karsiti , Mohd Noh
Format: Conference or Workshop Item
Published: 2010
Subjects:
Online Access:http://eprints.utp.edu.my/4057/1/freeabs_all.jsp%3Freload%3Dtrue%26arnumber%3D5489153
http://eprints.utp.edu.my/4057/
Tags: Add Tag
No Tags, Be the first to tag this record!
Be the first to leave a comment!
You must be logged in first