Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards
Wood is one of the primary combustible fuels used for Class A fire tests for clean agent fire suppression systems. The species classified in the standards, on the other hand, did not originate locally and are hardly found. It is overpriced to obtain in small quantities for the sake of the experiment...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Springer Science and Business Media Deutschland GmbH
2022
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126700754&doi=10.1007%2f978-3-030-92964-0_3&partnerID=40&md5=1b8f5aa0ff3148a6beeae478e052db82 http://eprints.utp.edu.my/33293/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.33293 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.332932022-07-26T06:35:01Z Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards Shukor, J.�A. Razak, M.A.-H.A. Hassan, A. Jamian, R. Rani, A.M.A. Wood is one of the primary combustible fuels used for Class A fire tests for clean agent fire suppression systems. The species classified in the standards, on the other hand, did not originate locally and are hardly found. It is overpriced to obtain in small quantities for the sake of the experimental test. Thorough investigations were suggested to validate the use of the proposed material, including verifying the species of the specimen, burning test, and conducting wood moisture content verification using oven-dry method to ensure the quality of combustible fuel for the final test as per standard requirement. The aim of this study is to justify the use of unspecified wood to meet the appropriate requirements for performing a fire crib test. As a result, the pinewood specifications were nearly and within the minimum criterion for performing the fire crib test. © 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG. Springer Science and Business Media Deutschland GmbH 2022 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126700754&doi=10.1007%2f978-3-030-92964-0_3&partnerID=40&md5=1b8f5aa0ff3148a6beeae478e052db82 Shukor, J.�A. and Razak, M.A.-H.A. and Hassan, A. and Jamian, R. and Rani, A.M.A. (2022) Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards. Advanced Structured Materials, 162 . pp. 19-27. http://eprints.utp.edu.my/33293/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Wood is one of the primary combustible fuels used for Class A fire tests for clean agent fire suppression systems. The species classified in the standards, on the other hand, did not originate locally and are hardly found. It is overpriced to obtain in small quantities for the sake of the experimental test. Thorough investigations were suggested to validate the use of the proposed material, including verifying the species of the specimen, burning test, and conducting wood moisture content verification using oven-dry method to ensure the quality of combustible fuel for the final test as per standard requirement. The aim of this study is to justify the use of unspecified wood to meet the appropriate requirements for performing a fire crib test. As a result, the pinewood specifications were nearly and within the minimum criterion for performing the fire crib test. © 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG. |
format |
Article |
author |
Shukor, J.�A. Razak, M.A.-H.A. Hassan, A. Jamian, R. Rani, A.M.A. |
spellingShingle |
Shukor, J.�A. Razak, M.A.-H.A. Hassan, A. Jamian, R. Rani, A.M.A. Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
author_facet |
Shukor, J.�A. Razak, M.A.-H.A. Hassan, A. Jamian, R. Rani, A.M.A. |
author_sort |
Shukor, J.�A. |
title |
Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
title_short |
Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
title_full |
Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
title_fullStr |
Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
title_full_unstemmed |
Determining the Alternative Type of Wood for Class a Fire Crib Test According to UL 2166 Standards |
title_sort |
determining the alternative type of wood for class a fire crib test according to ul 2166 standards |
publisher |
Springer Science and Business Media Deutschland GmbH |
publishDate |
2022 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126700754&doi=10.1007%2f978-3-030-92964-0_3&partnerID=40&md5=1b8f5aa0ff3148a6beeae478e052db82 http://eprints.utp.edu.my/33293/ |
_version_ |
1739833202182193152 |
score |
13.211869 |