Analysis of stability aspects of a large constant power load in a local grid

This paper investigate the problem of instability of constant power load (CPL) fed via a diode bridge rectifier connected in a local AC distribution system fed by wind farm with energy storage system installed. Analysis and simulation illustrates first that the instability as a function of the vario...

Full description

Saved in:
Bibliographic Details
Main Authors: Romlie, M.F., Klumpner, C., Rashed, M., Odavic, M., Asher, G.
Format: Conference or Workshop Item
Published: 2013
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84890150241&doi=10.1109%2fEPE.2013.6634481&partnerID=40&md5=4c3c4a661b838c455febebaa72826d5e
http://eprints.utp.edu.my/32476/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.32476
record_format eprints
spelling my.utp.eprints.324762022-03-29T14:03:43Z Analysis of stability aspects of a large constant power load in a local grid Romlie, M.F. Klumpner, C. Rashed, M. Odavic, M. Asher, G. This paper investigate the problem of instability of constant power load (CPL) fed via a diode bridge rectifier connected in a local AC distribution system fed by wind farm with energy storage system installed. Analysis and simulation illustrates first that the instability as a function of the various system parameters, then control based solutions for improving the stability is proposed and verified by analytical method and simulation in PSCAD. © 2013 IEEE. 2013 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84890150241&doi=10.1109%2fEPE.2013.6634481&partnerID=40&md5=4c3c4a661b838c455febebaa72826d5e Romlie, M.F. and Klumpner, C. and Rashed, M. and Odavic, M. and Asher, G. (2013) Analysis of stability aspects of a large constant power load in a local grid. In: UNSPECIFIED. http://eprints.utp.edu.my/32476/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This paper investigate the problem of instability of constant power load (CPL) fed via a diode bridge rectifier connected in a local AC distribution system fed by wind farm with energy storage system installed. Analysis and simulation illustrates first that the instability as a function of the various system parameters, then control based solutions for improving the stability is proposed and verified by analytical method and simulation in PSCAD. © 2013 IEEE.
format Conference or Workshop Item
author Romlie, M.F.
Klumpner, C.
Rashed, M.
Odavic, M.
Asher, G.
spellingShingle Romlie, M.F.
Klumpner, C.
Rashed, M.
Odavic, M.
Asher, G.
Analysis of stability aspects of a large constant power load in a local grid
author_facet Romlie, M.F.
Klumpner, C.
Rashed, M.
Odavic, M.
Asher, G.
author_sort Romlie, M.F.
title Analysis of stability aspects of a large constant power load in a local grid
title_short Analysis of stability aspects of a large constant power load in a local grid
title_full Analysis of stability aspects of a large constant power load in a local grid
title_fullStr Analysis of stability aspects of a large constant power load in a local grid
title_full_unstemmed Analysis of stability aspects of a large constant power load in a local grid
title_sort analysis of stability aspects of a large constant power load in a local grid
publishDate 2013
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84890150241&doi=10.1109%2fEPE.2013.6634481&partnerID=40&md5=4c3c4a661b838c455febebaa72826d5e
http://eprints.utp.edu.my/32476/
_version_ 1738657392228302848
score 13.251813