Spatio-temporal droplet size statistics in developing spray of starchy solution

In the given research, the spray jet breakup of a modified starch solution was studied as a function of jet injection time and nozzle orifice diameter. The starch-urea-borax solution was prepared and tested with three axisymmetric full cone nozzles at service temperature of 80°C and the injection p...

Full description

Saved in:
Bibliographic Details
Main Authors: Naz, M.Y., Sulaiman, S.A., Ariwahjoedi, B.
Format: Conference or Workshop Item
Published: American Institute of Physics Inc. 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042576092&doi=10.1063%2f1.4919171&partnerID=40&md5=065e8803d239dd1acb23767aee850d91
http://eprints.utp.edu.my/31469/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.31469
record_format eprints
spelling my.utp.eprints.314692022-03-26T03:20:12Z Spatio-temporal droplet size statistics in developing spray of starchy solution Naz, M.Y. Sulaiman, S.A. Ariwahjoedi, B. In the given research, the spray jet breakup of a modified starch solution was studied as a function of jet injection time and nozzle orifice diameter. The starch-urea-borax solution was prepared and tested with three axisymmetric full cone nozzles at service temperature of 80°C and the injection pressure of 5 bar. It is worth mentioning that no jet breakup was seen below these temperature and pressure values. The imaging studies on the time based spray evolution revealed monotonic increase in both; spray cone angle and tip penetration with an increase in injection time form 0-300 mm. Hereinafter, both parameters exhibited constants value over injection time. Phase Doppler Anemometry (PDA) measurements of the droplet size revealed significant decrease in the Sauter Mean Diameter (SMD) along the spray centerline. However, a steady decrease in SMD was seen towards the spray boundary. For fixed injection time of 300 ms, the overall SMD was decreased from 112 to 71 μm at 60 mm downstream, from 102 to 64 μm at 100 mm downstream and from 85 to 61 μm at 140 mm downstream with an increase in orifice diameter from 1.19 to 1.59 mm. © 2015 AIP Publishing LLC. American Institute of Physics Inc. 2015 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042576092&doi=10.1063%2f1.4919171&partnerID=40&md5=065e8803d239dd1acb23767aee850d91 Naz, M.Y. and Sulaiman, S.A. and Ariwahjoedi, B. (2015) Spatio-temporal droplet size statistics in developing spray of starchy solution. In: UNSPECIFIED. http://eprints.utp.edu.my/31469/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In the given research, the spray jet breakup of a modified starch solution was studied as a function of jet injection time and nozzle orifice diameter. The starch-urea-borax solution was prepared and tested with three axisymmetric full cone nozzles at service temperature of 80°C and the injection pressure of 5 bar. It is worth mentioning that no jet breakup was seen below these temperature and pressure values. The imaging studies on the time based spray evolution revealed monotonic increase in both; spray cone angle and tip penetration with an increase in injection time form 0-300 mm. Hereinafter, both parameters exhibited constants value over injection time. Phase Doppler Anemometry (PDA) measurements of the droplet size revealed significant decrease in the Sauter Mean Diameter (SMD) along the spray centerline. However, a steady decrease in SMD was seen towards the spray boundary. For fixed injection time of 300 ms, the overall SMD was decreased from 112 to 71 μm at 60 mm downstream, from 102 to 64 μm at 100 mm downstream and from 85 to 61 μm at 140 mm downstream with an increase in orifice diameter from 1.19 to 1.59 mm. © 2015 AIP Publishing LLC.
format Conference or Workshop Item
author Naz, M.Y.
Sulaiman, S.A.
Ariwahjoedi, B.
spellingShingle Naz, M.Y.
Sulaiman, S.A.
Ariwahjoedi, B.
Spatio-temporal droplet size statistics in developing spray of starchy solution
author_facet Naz, M.Y.
Sulaiman, S.A.
Ariwahjoedi, B.
author_sort Naz, M.Y.
title Spatio-temporal droplet size statistics in developing spray of starchy solution
title_short Spatio-temporal droplet size statistics in developing spray of starchy solution
title_full Spatio-temporal droplet size statistics in developing spray of starchy solution
title_fullStr Spatio-temporal droplet size statistics in developing spray of starchy solution
title_full_unstemmed Spatio-temporal droplet size statistics in developing spray of starchy solution
title_sort spatio-temporal droplet size statistics in developing spray of starchy solution
publisher American Institute of Physics Inc.
publishDate 2015
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042576092&doi=10.1063%2f1.4919171&partnerID=40&md5=065e8803d239dd1acb23767aee850d91
http://eprints.utp.edu.my/31469/
_version_ 1738657251963437056
score 13.211869