Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups
Shortcoming in the current design guidelines on externally bonded FRP shear strengthened members has initiated a motivation to relook the whole shear design approach. It is understood that effective FRP strain models used in present design guidelines are basically calibrated from the experimental da...
محفوظ في:
المؤلفون الرئيسيون: | , |
---|---|
التنسيق: | مقال |
منشور في: |
Elsevier Ltd
2015
|
الوصول للمادة أونلاين: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84936864539&doi=10.1016%2fj.compositesb.2015.05.004&partnerID=40&md5=14ed4a732acc7777331a3160357d5203 http://eprints.utp.edu.my/31432/ |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
id |
my.utp.eprints.31432 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.314322022-03-26T03:19:28Z Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups Teo, W. Hor, Y. Shortcoming in the current design guidelines on externally bonded FRP shear strengthened members has initiated a motivation to relook the whole shear design approach. It is understood that effective FRP strain models used in present design guidelines are basically calibrated from the experimental data based on the conservative and unrealistic 45-deg truss model. This paper is intended to propose an optimized truss model that derived from the principle of minimum total strain energy theorem to improve the present 45-deg truss model. The proposed optimized truss model is characterized with limiting failure criteria that reflects truly to the actual FRP strengthened beam behaviour. One of the most important failure criteria is the FRP debonding failure. To characterize it, limiting effective FRP strain εfrp,e model is incorporated into the optimized truss model. Six most recent effective strain models are chosen for the analysis, included three of the international design guidelines. Performance of each effective strain model will be evaluated along with the optimized and 45-deg truss models in order to assess their respective accuracy in predicting the FRP contribution to the shear strength. The validation of optimized truss model is done through comparing with experimental test results collected from the literature. The results obtained indicated that the optimized truss model is indeed more viable representative to the actual internal stress distribution and accurate than existing 45-deg truss model. So it might have a great potential to be used in the derivation of a new effective FRP strain model that can be implemented in the current design guidelines. © 2015 Elsevier Ltd. All rights reserved. Elsevier Ltd 2015 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84936864539&doi=10.1016%2fj.compositesb.2015.05.004&partnerID=40&md5=14ed4a732acc7777331a3160357d5203 Teo, W. and Hor, Y. (2015) Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups. Composites Part B: Engineering, 80 . pp. 385-398. http://eprints.utp.edu.my/31432/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Shortcoming in the current design guidelines on externally bonded FRP shear strengthened members has initiated a motivation to relook the whole shear design approach. It is understood that effective FRP strain models used in present design guidelines are basically calibrated from the experimental data based on the conservative and unrealistic 45-deg truss model. This paper is intended to propose an optimized truss model that derived from the principle of minimum total strain energy theorem to improve the present 45-deg truss model. The proposed optimized truss model is characterized with limiting failure criteria that reflects truly to the actual FRP strengthened beam behaviour. One of the most important failure criteria is the FRP debonding failure. To characterize it, limiting effective FRP strain εfrp,e model is incorporated into the optimized truss model. Six most recent effective strain models are chosen for the analysis, included three of the international design guidelines. Performance of each effective strain model will be evaluated along with the optimized and 45-deg truss models in order to assess their respective accuracy in predicting the FRP contribution to the shear strength. The validation of optimized truss model is done through comparing with experimental test results collected from the literature. The results obtained indicated that the optimized truss model is indeed more viable representative to the actual internal stress distribution and accurate than existing 45-deg truss model. So it might have a great potential to be used in the derivation of a new effective FRP strain model that can be implemented in the current design guidelines. © 2015 Elsevier Ltd. All rights reserved. |
format |
Article |
author |
Teo, W. Hor, Y. |
spellingShingle |
Teo, W. Hor, Y. Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
author_facet |
Teo, W. Hor, Y. |
author_sort |
Teo, W. |
title |
Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
title_short |
Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
title_full |
Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
title_fullStr |
Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
title_full_unstemmed |
Suitability of optimized truss model to predict the FRP contribution to shear resistance for externally bonded FRP strengthened RC beams without internal stirrups |
title_sort |
suitability of optimized truss model to predict the frp contribution to shear resistance for externally bonded frp strengthened rc beams without internal stirrups |
publisher |
Elsevier Ltd |
publishDate |
2015 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84936864539&doi=10.1016%2fj.compositesb.2015.05.004&partnerID=40&md5=14ed4a732acc7777331a3160357d5203 http://eprints.utp.edu.my/31432/ |
_version_ |
1738657246827511808 |
score |
13.250246 |