Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
MDPI
2021
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc http://eprints.utp.edu.my/29626/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.29626 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.296262022-03-29T05:21:04Z Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes Javed, M.F. Rafiq, H. Khan, M.A. Aslam, F. Musarat, M.A. Vatin, N.I. This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10 strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004). © 2021 by the authors. Licensee MDPI, Basel, Switzerland. MDPI 2021 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc Javed, M.F. and Rafiq, H. and Khan, M.A. and Aslam, F. and Musarat, M.A. and Vatin, N.I. (2021) Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes. Crystals, 11 (12). http://eprints.utp.edu.my/29626/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10 strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004). © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
format |
Article |
author |
Javed, M.F. Rafiq, H. Khan, M.A. Aslam, F. Musarat, M.A. Vatin, N.I. |
spellingShingle |
Javed, M.F. Rafiq, H. Khan, M.A. Aslam, F. Musarat, M.A. Vatin, N.I. Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
author_facet |
Javed, M.F. Rafiq, H. Khan, M.A. Aslam, F. Musarat, M.A. Vatin, N.I. |
author_sort |
Javed, M.F. |
title |
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
title_short |
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
title_full |
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
title_fullStr |
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
title_full_unstemmed |
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes |
title_sort |
axial behavior of concrete-filled double-skin tubular stub columns incorporating pvc pipes |
publisher |
MDPI |
publishDate |
2021 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc http://eprints.utp.edu.my/29626/ |
_version_ |
1738656992545734656 |
score |
13.211869 |