Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes

This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube...

Full description

Saved in:
Bibliographic Details
Main Authors: Javed, M.F., Rafiq, H., Khan, M.A., Aslam, F., Musarat, M.A., Vatin, N.I.
Format: Article
Published: MDPI 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc
http://eprints.utp.edu.my/29626/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.29626
record_format eprints
spelling my.utp.eprints.296262022-03-29T05:21:04Z Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes Javed, M.F. Rafiq, H. Khan, M.A. Aslam, F. Musarat, M.A. Vatin, N.I. This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10 strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004). © 2021 by the authors. Licensee MDPI, Basel, Switzerland. MDPI 2021 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc Javed, M.F. and Rafiq, H. and Khan, M.A. and Aslam, F. and Musarat, M.A. and Vatin, N.I. (2021) Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes. Crystals, 11 (12). http://eprints.utp.edu.my/29626/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This experimental study presents concrete-filled double-skin tubular columns and demon-strates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10 strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004). © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
format Article
author Javed, M.F.
Rafiq, H.
Khan, M.A.
Aslam, F.
Musarat, M.A.
Vatin, N.I.
spellingShingle Javed, M.F.
Rafiq, H.
Khan, M.A.
Aslam, F.
Musarat, M.A.
Vatin, N.I.
Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
author_facet Javed, M.F.
Rafiq, H.
Khan, M.A.
Aslam, F.
Musarat, M.A.
Vatin, N.I.
author_sort Javed, M.F.
title Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
title_short Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
title_full Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
title_fullStr Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
title_full_unstemmed Axial behavior of concrete-filled double-skin tubular stub columns incorporating PVC pipes
title_sort axial behavior of concrete-filled double-skin tubular stub columns incorporating pvc pipes
publisher MDPI
publishDate 2021
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85120040201&doi=10.3390%2fcryst11121434&partnerID=40&md5=43c22789c5bffc97ef178d74bf3c97bc
http://eprints.utp.edu.my/29626/
_version_ 1738656992545734656
score 13.211869