Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill

In this study, the performance of a semi-aerobic landfill was monitored through the analysis of leachate composition collected from different leachate ponds; collection pump (CP), equalization pond (EQ) and aerated pond (AP). The landfill site is located in the tropical environment of the central re...

Full description

Saved in:
Bibliographic Details
Main Authors: Olisa, E., Sapari, N., Malakahmad, A., Ezechi, E.H., Riahi, A., Salihi, I.U., Orji, K.U.
Format: Article
Published: Trans Tech Publications Ltd 2016
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964950992&doi=10.4028%2fwww.scientific.net%2fJERA.22.68&partnerID=40&md5=9ab21ba856e0483c1f60bc52667afcb4
http://eprints.utp.edu.my/25828/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.25828
record_format eprints
spelling my.utp.eprints.258282021-08-27T13:06:53Z Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill Olisa, E. Sapari, N. Malakahmad, A. Ezechi, E.H. Riahi, A. Salihi, I.U. Orji, K.U. In this study, the performance of a semi-aerobic landfill was monitored through the analysis of leachate composition collected from different leachate ponds; collection pump (CP), equalization pond (EQ) and aerated pond (AP). The landfill site is located in the tropical environment of the central region of Malaysia. Malaysia has adopted the semi-aerobic system of landfill; however this landfill produces leachate with high organic matter content which can be converted to methane gas under anaerobic condition and it also allows the escape of landfill gas (LFG) from the leachate collection pipes. Twenty parameters were analyzed and the mean values of the parameters for leachate at the CP, EQ and AP, which include; pH (8.24, 8.00 and 8.73), total kjeldahl nitrogen (3987.25, 8744.6, 1927.31 TKN-N), ammonia-N (3726, 3800, 1560 mg/L NH3- N), nitrate (26.7, 33.3, 25 mg/L NO3-N), total phosphorus (0.85, 0.78, 0.92 mg/L PO43-), BOD5 (305, 311.3, 201 mg/L), COD (16100, 14587, 12780 mg/L), BOD5/COD (0.019, 0.021, 0.016), turbidity (405, 735, 940 NTU), colour (3991, 4122, 3412 Pt Co), TSS (109.3, 58, 50.7 mg/L), EC (32.8, 21.9, 37.0 mS/cm) and TDS (21.98, 14.7, 24.8 mg/L) were recorded appropriately. The results realized from the analysis of the three ponds were compared with data published by other researchers and also the standards specified by the Malaysia Environmental Quality (MEQ) Act 1974. The results obtained indicate that the leachate from the aerated pond could remove some of the pollutants and was better stabilized as compared to the leachate from the pump and equalization ponds. It is also found that the aeration process in aerated pond could enhance the reduction of pollutants in the leachate. The measured leachates would require appropriate treatment methods in order to reduce the pollutants to meet the discharge standard before releasing them into water courses. © 2016 Trans Tech Publications, Switzerland. Trans Tech Publications Ltd 2016 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964950992&doi=10.4028%2fwww.scientific.net%2fJERA.22.68&partnerID=40&md5=9ab21ba856e0483c1f60bc52667afcb4 Olisa, E. and Sapari, N. and Malakahmad, A. and Ezechi, E.H. and Riahi, A. and Salihi, I.U. and Orji, K.U. (2016) Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill. International Journal of Engineering Research in Africa, 22 . pp. 68-82. http://eprints.utp.edu.my/25828/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In this study, the performance of a semi-aerobic landfill was monitored through the analysis of leachate composition collected from different leachate ponds; collection pump (CP), equalization pond (EQ) and aerated pond (AP). The landfill site is located in the tropical environment of the central region of Malaysia. Malaysia has adopted the semi-aerobic system of landfill; however this landfill produces leachate with high organic matter content which can be converted to methane gas under anaerobic condition and it also allows the escape of landfill gas (LFG) from the leachate collection pipes. Twenty parameters were analyzed and the mean values of the parameters for leachate at the CP, EQ and AP, which include; pH (8.24, 8.00 and 8.73), total kjeldahl nitrogen (3987.25, 8744.6, 1927.31 TKN-N), ammonia-N (3726, 3800, 1560 mg/L NH3- N), nitrate (26.7, 33.3, 25 mg/L NO3-N), total phosphorus (0.85, 0.78, 0.92 mg/L PO43-), BOD5 (305, 311.3, 201 mg/L), COD (16100, 14587, 12780 mg/L), BOD5/COD (0.019, 0.021, 0.016), turbidity (405, 735, 940 NTU), colour (3991, 4122, 3412 Pt Co), TSS (109.3, 58, 50.7 mg/L), EC (32.8, 21.9, 37.0 mS/cm) and TDS (21.98, 14.7, 24.8 mg/L) were recorded appropriately. The results realized from the analysis of the three ponds were compared with data published by other researchers and also the standards specified by the Malaysia Environmental Quality (MEQ) Act 1974. The results obtained indicate that the leachate from the aerated pond could remove some of the pollutants and was better stabilized as compared to the leachate from the pump and equalization ponds. It is also found that the aeration process in aerated pond could enhance the reduction of pollutants in the leachate. The measured leachates would require appropriate treatment methods in order to reduce the pollutants to meet the discharge standard before releasing them into water courses. © 2016 Trans Tech Publications, Switzerland.
format Article
author Olisa, E.
Sapari, N.
Malakahmad, A.
Ezechi, E.H.
Riahi, A.
Salihi, I.U.
Orji, K.U.
spellingShingle Olisa, E.
Sapari, N.
Malakahmad, A.
Ezechi, E.H.
Riahi, A.
Salihi, I.U.
Orji, K.U.
Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
author_facet Olisa, E.
Sapari, N.
Malakahmad, A.
Ezechi, E.H.
Riahi, A.
Salihi, I.U.
Orji, K.U.
author_sort Olisa, E.
title Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
title_short Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
title_full Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
title_fullStr Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
title_full_unstemmed Evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
title_sort evaluation of leachate characteristics from different leachate ponds in a semi-aerobic landfill
publisher Trans Tech Publications Ltd
publishDate 2016
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964950992&doi=10.4028%2fwww.scientific.net%2fJERA.22.68&partnerID=40&md5=9ab21ba856e0483c1f60bc52667afcb4
http://eprints.utp.edu.my/25828/
_version_ 1738656785612406784
score 13.211869