Explosion potential assessment of heat exchanger network at the preliminary design stage

The failure of Shell and Tube Heat Exchangers (STHE) is being extensively observed in the chemical process industries. This failure can cause enormous production loss and have a potential of dangerous consequences such as an explosion, fire and toxic release scenarios. There is an urgent need for as...

Full description

Saved in:
Bibliographic Details
Main Authors: Pasha, M., Zaini, D., Shariff, A.M.
Format: Article
Published: Taylor's University 2016
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84986220517&partnerID=40&md5=6b8af13c6bd253cd420032dfc482c3d4
http://eprints.utp.edu.my/25638/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.25638
record_format eprints
spelling my.utp.eprints.256382021-08-27T10:00:06Z Explosion potential assessment of heat exchanger network at the preliminary design stage Pasha, M. Zaini, D. Shariff, A.M. The failure of Shell and Tube Heat Exchangers (STHE) is being extensively observed in the chemical process industries. This failure can cause enormous production loss and have a potential of dangerous consequences such as an explosion, fire and toxic release scenarios. There is an urgent need for assessing the explosion potential of shell and tube heat exchanger at the preliminary design stage. In current work, inherent safety index based approach is used to resolve the highlighted issue. Inherent Safety Index for Shell and Tube Heat Exchanger (ISISTHE) is a newly developed index for assessing the inherent safety level of a STHE at the preliminary design stage. This index is composed of preliminary design variables and integrated with the process design simulator (Aspen HYSYS). Process information can easily be transferred from process design simulator to MS Excel spreadsheet owing to this integration. This index could potentially facilitate the design engineer to analyse the worst heat exchanger in the heat exchanger network. Typical heat exchanger network of the steam reforming process is presented as a case study and the worst heat exchanger of this network has been identified. It is inferred from this analysis that shell and tube heat exchangers possess high operating pressure, corrected mean temperature difference (CMTD) and flammability and reactive potential needs to be critically analysed at the preliminary design stage. © School of Engineering, Taylor�s University. Taylor's University 2016 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84986220517&partnerID=40&md5=6b8af13c6bd253cd420032dfc482c3d4 Pasha, M. and Zaini, D. and Shariff, A.M. (2016) Explosion potential assessment of heat exchanger network at the preliminary design stage. Journal of Engineering Science and Technology, 11 (Specia). pp. 30-42. http://eprints.utp.edu.my/25638/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The failure of Shell and Tube Heat Exchangers (STHE) is being extensively observed in the chemical process industries. This failure can cause enormous production loss and have a potential of dangerous consequences such as an explosion, fire and toxic release scenarios. There is an urgent need for assessing the explosion potential of shell and tube heat exchanger at the preliminary design stage. In current work, inherent safety index based approach is used to resolve the highlighted issue. Inherent Safety Index for Shell and Tube Heat Exchanger (ISISTHE) is a newly developed index for assessing the inherent safety level of a STHE at the preliminary design stage. This index is composed of preliminary design variables and integrated with the process design simulator (Aspen HYSYS). Process information can easily be transferred from process design simulator to MS Excel spreadsheet owing to this integration. This index could potentially facilitate the design engineer to analyse the worst heat exchanger in the heat exchanger network. Typical heat exchanger network of the steam reforming process is presented as a case study and the worst heat exchanger of this network has been identified. It is inferred from this analysis that shell and tube heat exchangers possess high operating pressure, corrected mean temperature difference (CMTD) and flammability and reactive potential needs to be critically analysed at the preliminary design stage. © School of Engineering, Taylor�s University.
format Article
author Pasha, M.
Zaini, D.
Shariff, A.M.
spellingShingle Pasha, M.
Zaini, D.
Shariff, A.M.
Explosion potential assessment of heat exchanger network at the preliminary design stage
author_facet Pasha, M.
Zaini, D.
Shariff, A.M.
author_sort Pasha, M.
title Explosion potential assessment of heat exchanger network at the preliminary design stage
title_short Explosion potential assessment of heat exchanger network at the preliminary design stage
title_full Explosion potential assessment of heat exchanger network at the preliminary design stage
title_fullStr Explosion potential assessment of heat exchanger network at the preliminary design stage
title_full_unstemmed Explosion potential assessment of heat exchanger network at the preliminary design stage
title_sort explosion potential assessment of heat exchanger network at the preliminary design stage
publisher Taylor's University
publishDate 2016
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84986220517&partnerID=40&md5=6b8af13c6bd253cd420032dfc482c3d4
http://eprints.utp.edu.my/25638/
_version_ 1738656758759424000
score 13.211869