Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings

Intumescent fire retardant coating is widely used in the industry for protecting steel from high temperature and fire incident. The coating's application can be found in the oil and gas industries especially in the offshore structures due to its ability to withstand high temperature and severe...

Full description

Saved in:
Bibliographic Details
Main Authors: Amir, N., Jalil, A.N.A., Ahmad, F.
Format: Article
Published: Asian Research Publishing Network 2016
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84994229375&partnerID=40&md5=1cda7b89880983f7111d3eded8ba71e7
http://eprints.utp.edu.my/25468/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.25468
record_format eprints
spelling my.utp.eprints.254682021-08-27T13:01:39Z Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings Amir, N. Jalil, A.N.A. Ahmad, F. Intumescent fire retardant coating is widely used in the industry for protecting steel from high temperature and fire incident. The coating's application can be found in the oil and gas industries especially in the offshore structures due to its ability to withstand high temperature and severe weather. However, char strength of the existing intumescent coating can be further improved by fibre reinforcement. Previously, various researches on intumescent coating were conducted using single fibre with limited study on the hybrid fibre reinforced intumescent coating. The project examined the effects of adding hybrid fibres, exploring the mechanical and char characteristics in increasing the fire performance of the coating. The study was focused on adding glass wool fibre (G) and Rockwool fibre (R) as the hybrid reinforcement using two fibre lengths; 6 mm and 12 mm, and at 10 by weight percentage with three combinations of 3:7, 5:5 and 7:3. The investigation involved determination of potential fire resistance of the hybrid fibre reinforced intumescent coatings at various compositions and lengths of the fibres. The properties and performance of the coatings were based on the chars developed by the coatings in the furnace test. The coatings and their chars were characterized using X-Ray Fluorescence (XRF) and Scanning Electron Microscope (SEM). Finally, the chars produced were tested for strength performance test. In summary increased in the Rockwool fibre from 3 to 7 in the hybrid fibres content had produced higher char expansion (by 15.7), lower weight loss (by 22.8) as well as better char performance against loading (by 37). ©2006-2016 Asian Research Publishing Network (ARPN). Asian Research Publishing Network 2016 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84994229375&partnerID=40&md5=1cda7b89880983f7111d3eded8ba71e7 Amir, N. and Jalil, A.N.A. and Ahmad, F. (2016) Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings. ARPN Journal of Engineering and Applied Sciences, 11 (20). pp. 12268-12274. http://eprints.utp.edu.my/25468/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Intumescent fire retardant coating is widely used in the industry for protecting steel from high temperature and fire incident. The coating's application can be found in the oil and gas industries especially in the offshore structures due to its ability to withstand high temperature and severe weather. However, char strength of the existing intumescent coating can be further improved by fibre reinforcement. Previously, various researches on intumescent coating were conducted using single fibre with limited study on the hybrid fibre reinforced intumescent coating. The project examined the effects of adding hybrid fibres, exploring the mechanical and char characteristics in increasing the fire performance of the coating. The study was focused on adding glass wool fibre (G) and Rockwool fibre (R) as the hybrid reinforcement using two fibre lengths; 6 mm and 12 mm, and at 10 by weight percentage with three combinations of 3:7, 5:5 and 7:3. The investigation involved determination of potential fire resistance of the hybrid fibre reinforced intumescent coatings at various compositions and lengths of the fibres. The properties and performance of the coatings were based on the chars developed by the coatings in the furnace test. The coatings and their chars were characterized using X-Ray Fluorescence (XRF) and Scanning Electron Microscope (SEM). Finally, the chars produced were tested for strength performance test. In summary increased in the Rockwool fibre from 3 to 7 in the hybrid fibres content had produced higher char expansion (by 15.7), lower weight loss (by 22.8) as well as better char performance against loading (by 37). ©2006-2016 Asian Research Publishing Network (ARPN).
format Article
author Amir, N.
Jalil, A.N.A.
Ahmad, F.
spellingShingle Amir, N.
Jalil, A.N.A.
Ahmad, F.
Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
author_facet Amir, N.
Jalil, A.N.A.
Ahmad, F.
author_sort Amir, N.
title Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
title_short Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
title_full Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
title_fullStr Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
title_full_unstemmed Characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
title_sort characterization and study of char performance of glass wool and rockwool hybrid fibre reinforced intumescent coatings
publisher Asian Research Publishing Network
publishDate 2016
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84994229375&partnerID=40&md5=1cda7b89880983f7111d3eded8ba71e7
http://eprints.utp.edu.my/25468/
_version_ 1738656734273077248
score 13.211869