Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants

In this study, the microclimate of the test room was regulated using thermoelectric air duct cooling system (TE-AD) operated at input powers-240 W, 360 W, 480 W, 600 W, 720 W, and 840 W, on subsequent nights. Fifteen (15) healthy male volunteers were recruited to sleep under these test conditions an...

Full description

Saved in:
Bibliographic Details
Main Authors: Irshad, K., Algarni, S., Ahmad, M.T., Irfan, S.A., Habib, K., Abdelmohimen, M.A.H., Hasan Zahir, Md., Sayeed Ahmed, G.M.
Format: Article
Published: MDPI AG 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072721928&doi=10.3390%2fen12193695&partnerID=40&md5=5b7f8a5c1c9df8bec6085f9469e43be6
http://eprints.utp.edu.my/24932/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.24932
record_format eprints
spelling my.utp.eprints.249322021-08-27T08:26:04Z Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants Irshad, K. Algarni, S. Ahmad, M.T. Irfan, S.A. Habib, K. Abdelmohimen, M.A.H. Hasan Zahir, Md. Sayeed Ahmed, G.M. In this study, the microclimate of the test room was regulated using thermoelectric air duct cooling system (TE-AD) operated at input powers-240 W, 360 W, 480 W, 600 W, 720 W, and 840 W, on subsequent nights. Fifteen (15) healthy male volunteers were recruited to sleep under these test conditions and their sleep quality was assessed by studying objective measures such as sleep onset latency (SOL), mean skin temperature and heart rate as well as subjective parameters like predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD). There was a consistent improvement on all studied parameters when the power of the system was increased from 240 W to 720 W. The mean sleep onset latency time was reduced from (M = 40.7 +/� 0.98 min) to (M = 18.33 +/� 1.18 min) when the operating power was increased from 240 W to 720 W, denoting an improvement in sleep quality. However, increasing the power further to 840 W resulted in deteriorating cooling performance of the TE-AD system leading to an increase in temperature of the test room and reduction in sleep comfort. Analysis of subjective indices of thermal comfort viz. PMV and PPD revealed that subjects are highly sensitive towards variations in microclimate achieved by changing the operating power of the TE-AD. This device was also found to be environmentally sustainable, with estimated reduction in CO2 emission calculated to be around 38 as compared to the conventional air-conditioning. © 2019 by the authors. MDPI AG 2019 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072721928&doi=10.3390%2fen12193695&partnerID=40&md5=5b7f8a5c1c9df8bec6085f9469e43be6 Irshad, K. and Algarni, S. and Ahmad, M.T. and Irfan, S.A. and Habib, K. and Abdelmohimen, M.A.H. and Hasan Zahir, Md. and Sayeed Ahmed, G.M. (2019) Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants. Energies, 12 (19). http://eprints.utp.edu.my/24932/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In this study, the microclimate of the test room was regulated using thermoelectric air duct cooling system (TE-AD) operated at input powers-240 W, 360 W, 480 W, 600 W, 720 W, and 840 W, on subsequent nights. Fifteen (15) healthy male volunteers were recruited to sleep under these test conditions and their sleep quality was assessed by studying objective measures such as sleep onset latency (SOL), mean skin temperature and heart rate as well as subjective parameters like predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD). There was a consistent improvement on all studied parameters when the power of the system was increased from 240 W to 720 W. The mean sleep onset latency time was reduced from (M = 40.7 +/� 0.98 min) to (M = 18.33 +/� 1.18 min) when the operating power was increased from 240 W to 720 W, denoting an improvement in sleep quality. However, increasing the power further to 840 W resulted in deteriorating cooling performance of the TE-AD system leading to an increase in temperature of the test room and reduction in sleep comfort. Analysis of subjective indices of thermal comfort viz. PMV and PPD revealed that subjects are highly sensitive towards variations in microclimate achieved by changing the operating power of the TE-AD. This device was also found to be environmentally sustainable, with estimated reduction in CO2 emission calculated to be around 38 as compared to the conventional air-conditioning. © 2019 by the authors.
format Article
author Irshad, K.
Algarni, S.
Ahmad, M.T.
Irfan, S.A.
Habib, K.
Abdelmohimen, M.A.H.
Hasan Zahir, Md.
Sayeed Ahmed, G.M.
spellingShingle Irshad, K.
Algarni, S.
Ahmad, M.T.
Irfan, S.A.
Habib, K.
Abdelmohimen, M.A.H.
Hasan Zahir, Md.
Sayeed Ahmed, G.M.
Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
author_facet Irshad, K.
Algarni, S.
Ahmad, M.T.
Irfan, S.A.
Habib, K.
Abdelmohimen, M.A.H.
Hasan Zahir, Md.
Sayeed Ahmed, G.M.
author_sort Irshad, K.
title Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
title_short Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
title_full Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
title_fullStr Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
title_full_unstemmed Microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
title_sort microclimate thermal management using thermoelectric air-cooling duct system operated at five incremental powers and its effect on sleep adaptation of the occupants
publisher MDPI AG
publishDate 2019
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072721928&doi=10.3390%2fen12193695&partnerID=40&md5=5b7f8a5c1c9df8bec6085f9469e43be6
http://eprints.utp.edu.my/24932/
_version_ 1738656659679477760
score 13.211869