Below-Grade Sulfur Storage Pits in Oil Refineries: A Review

The analysis of subsurface structures has always remained a challenge for construction engineer, especially the below-grade sulfur storage pit. A sulfur pit temporarily accommodates elemental sulfur extracted from oil refineries through a Sulfur Recovery Unit (SRU) and conveyed further to different...

Full description

Saved in:
Bibliographic Details
Main Authors: Anwar, A., Mohammed, B.S., Liew, M.S., Wahab, M.A., Zawawi, N.A.W.A.
Format: Article
Published: Springer 2019
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85074709754&doi=10.1007%2fs11668-019-00773-0&partnerID=40&md5=0328030ada16c78c050d52bdb2705d40
http://eprints.utp.edu.my/24849/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.24849
record_format eprints
spelling my.utp.eprints.248492021-08-27T08:44:38Z Below-Grade Sulfur Storage Pits in Oil Refineries: A Review Anwar, A. Mohammed, B.S. Liew, M.S. Wahab, M.A. Zawawi, N.A.W.A. The analysis of subsurface structures has always remained a challenge for construction engineer, especially the below-grade sulfur storage pit. A sulfur pit temporarily accommodates elemental sulfur extracted from oil refineries through a Sulfur Recovery Unit (SRU) and conveyed further to different transportation systems such as railcars, trucks or barges via a pumping system. The storage pit ensures that the elemental sulfur remains in its molten state, and further, the surrounding soil environment is protected. The operating temperature of below-grade sulfur storage pits range from 250 °F (121 °C) to 300 °F (149 °C) at which molten sulfur is kept in fluid form using submerged heating coils located at the pit base. The hazardous, corrosive and highly acidic environment causes severe concrete deterioration in the sulfur pit. The extensive concrete deterioration reduces the life span of the sulfur pit to even less than 10 years. The sulfuric acid formation is mainly responsible for the corrosive environment in the pit. The progression occurs from crack formation to delamination to spalling of concrete cover to corrosion, which finally degrades the structural durability and integrity. The heavily affected areas within the pit include the soffit of the roof slab and the walls in the headspace regions. This research paper presents the review of the various mechanisms in sulfur pit deterioration supported by industrial case studies and the absence of long-term durability performance in current industrial sulfur pit repair approaches. © 2019, ASM International. Springer 2019 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85074709754&doi=10.1007%2fs11668-019-00773-0&partnerID=40&md5=0328030ada16c78c050d52bdb2705d40 Anwar, A. and Mohammed, B.S. and Liew, M.S. and Wahab, M.A. and Zawawi, N.A.W.A. (2019) Below-Grade Sulfur Storage Pits in Oil Refineries: A Review. Journal of Failure Analysis and Prevention, 19 (6). pp. 1745-1760. http://eprints.utp.edu.my/24849/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The analysis of subsurface structures has always remained a challenge for construction engineer, especially the below-grade sulfur storage pit. A sulfur pit temporarily accommodates elemental sulfur extracted from oil refineries through a Sulfur Recovery Unit (SRU) and conveyed further to different transportation systems such as railcars, trucks or barges via a pumping system. The storage pit ensures that the elemental sulfur remains in its molten state, and further, the surrounding soil environment is protected. The operating temperature of below-grade sulfur storage pits range from 250 °F (121 °C) to 300 °F (149 °C) at which molten sulfur is kept in fluid form using submerged heating coils located at the pit base. The hazardous, corrosive and highly acidic environment causes severe concrete deterioration in the sulfur pit. The extensive concrete deterioration reduces the life span of the sulfur pit to even less than 10 years. The sulfuric acid formation is mainly responsible for the corrosive environment in the pit. The progression occurs from crack formation to delamination to spalling of concrete cover to corrosion, which finally degrades the structural durability and integrity. The heavily affected areas within the pit include the soffit of the roof slab and the walls in the headspace regions. This research paper presents the review of the various mechanisms in sulfur pit deterioration supported by industrial case studies and the absence of long-term durability performance in current industrial sulfur pit repair approaches. © 2019, ASM International.
format Article
author Anwar, A.
Mohammed, B.S.
Liew, M.S.
Wahab, M.A.
Zawawi, N.A.W.A.
spellingShingle Anwar, A.
Mohammed, B.S.
Liew, M.S.
Wahab, M.A.
Zawawi, N.A.W.A.
Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
author_facet Anwar, A.
Mohammed, B.S.
Liew, M.S.
Wahab, M.A.
Zawawi, N.A.W.A.
author_sort Anwar, A.
title Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
title_short Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
title_full Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
title_fullStr Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
title_full_unstemmed Below-Grade Sulfur Storage Pits in Oil Refineries: A Review
title_sort below-grade sulfur storage pits in oil refineries: a review
publisher Springer
publishDate 2019
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85074709754&doi=10.1007%2fs11668-019-00773-0&partnerID=40&md5=0328030ada16c78c050d52bdb2705d40
http://eprints.utp.edu.my/24849/
_version_ 1738656648092712960
score 13.211869