Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application

In the current study, a phase inversion scheme was employed to fabricate hydroxyapatite (HA)/polysulfone (PSF)-based asymmetric membranes using a film applicator with water as a solvent and nonsolvent exchanging medium. Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) spectroscopic stud...

Full description

Saved in:
Bibliographic Details
Main Authors: Zaman, S.U., Saif-ur-Rehman,, Zaman, M.K.U., Rafiq, S., Arshad, A., Khurram, M.S., Irfan, M., Saqib, S., Muhammad, N., Sharif, F., Bustam, M.A., Jamal, M., Khan, M.A., Waseem, M.A., Mukhtar, A., Wajeeh, S.
Format: Article
Published: Blackwell Publishing Inc. 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85109355892&doi=10.1111%2faor.14020&partnerID=40&md5=f7c98f18db8221016630e18b8b330529
http://eprints.utp.edu.my/23952/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.23952
record_format eprints
spelling my.utp.eprints.239522021-08-19T13:23:17Z Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application Zaman, S.U. Saif-ur-Rehman, Zaman, M.K.U. Rafiq, S. Arshad, A. Khurram, M.S. Irfan, M. Saqib, S. Muhammad, N. Irfan, M. Sharif, F. Bustam, M.A. Jamal, M. Khan, M.A. Waseem, M.A. Mukhtar, A. Wajeeh, S. In the current study, a phase inversion scheme was employed to fabricate hydroxyapatite (HA)/polysulfone (PSF)-based asymmetric membranes using a film applicator with water as a solvent and nonsolvent exchanging medium. Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) spectroscopic studies were conducted to confirm the bonding chemistry and purity of filler. The inherent thick nature of PSF generated sponge-like shape while the instantaneous demixing process produced finger-like pore networks in HA/PSF-based asymmetric membranes as exhibited by scanning electron microscope (SEM) micrographs. The FTIR spectra confirmed noncovalent weak attractions toward the polymer surface. The leaching ratio was evaluated to observe the dispersion behavior of HA filler in membrane composition. Hydrophilicity, pore profile, pure water permeation (PWP) flux, and molecular weight cutoff (MWCO) values of all formulated membranes were also calculated. Antifouling results revealed that HA modified PSF membranes exhibited 43 less adhesion of bovine serum albumin (BSA) together with >86 recovery of flux. Membrane composition showed 74 total resistance, out of which 60 was reversible resistance. Biocompatibility evaluation revealed that the modified membranes exhibited prothrombin time (PT), and thrombin time (TT) comparable with typical blood plasma, whereas proliferation of living cells over membrane surface proved its nontoxic behavior toward biomedical application. The urea and creatinine showed effective adsorption aptitude toward HA loaded PSF membranes. © 2021 International Center for Artificial Organs and Transplantation and Wiley Periodicals LLC. Blackwell Publishing Inc. 2021 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85109355892&doi=10.1111%2faor.14020&partnerID=40&md5=f7c98f18db8221016630e18b8b330529 Zaman, S.U. and Saif-ur-Rehman, and Zaman, M.K.U. and Rafiq, S. and Arshad, A. and Khurram, M.S. and Irfan, M. and Saqib, S. and Muhammad, N. and Irfan, M. and Sharif, F. and Bustam, M.A. and Jamal, M. and Khan, M.A. and Waseem, M.A. and Mukhtar, A. and Wajeeh, S. (2021) Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application. Artificial Organs . http://eprints.utp.edu.my/23952/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In the current study, a phase inversion scheme was employed to fabricate hydroxyapatite (HA)/polysulfone (PSF)-based asymmetric membranes using a film applicator with water as a solvent and nonsolvent exchanging medium. Fourier Transform Infrared (FTIR) and X-ray diffraction (XRD) spectroscopic studies were conducted to confirm the bonding chemistry and purity of filler. The inherent thick nature of PSF generated sponge-like shape while the instantaneous demixing process produced finger-like pore networks in HA/PSF-based asymmetric membranes as exhibited by scanning electron microscope (SEM) micrographs. The FTIR spectra confirmed noncovalent weak attractions toward the polymer surface. The leaching ratio was evaluated to observe the dispersion behavior of HA filler in membrane composition. Hydrophilicity, pore profile, pure water permeation (PWP) flux, and molecular weight cutoff (MWCO) values of all formulated membranes were also calculated. Antifouling results revealed that HA modified PSF membranes exhibited 43 less adhesion of bovine serum albumin (BSA) together with >86 recovery of flux. Membrane composition showed 74 total resistance, out of which 60 was reversible resistance. Biocompatibility evaluation revealed that the modified membranes exhibited prothrombin time (PT), and thrombin time (TT) comparable with typical blood plasma, whereas proliferation of living cells over membrane surface proved its nontoxic behavior toward biomedical application. The urea and creatinine showed effective adsorption aptitude toward HA loaded PSF membranes. © 2021 International Center for Artificial Organs and Transplantation and Wiley Periodicals LLC.
format Article
author Zaman, S.U.
Saif-ur-Rehman,
Zaman, M.K.U.
Rafiq, S.
Arshad, A.
Khurram, M.S.
Irfan, M.
Saqib, S.
Muhammad, N.
Irfan, M.
Sharif, F.
Bustam, M.A.
Jamal, M.
Khan, M.A.
Waseem, M.A.
Mukhtar, A.
Wajeeh, S.
spellingShingle Zaman, S.U.
Saif-ur-Rehman,
Zaman, M.K.U.
Rafiq, S.
Arshad, A.
Khurram, M.S.
Irfan, M.
Saqib, S.
Muhammad, N.
Irfan, M.
Sharif, F.
Bustam, M.A.
Jamal, M.
Khan, M.A.
Waseem, M.A.
Mukhtar, A.
Wajeeh, S.
Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
author_facet Zaman, S.U.
Saif-ur-Rehman,
Zaman, M.K.U.
Rafiq, S.
Arshad, A.
Khurram, M.S.
Irfan, M.
Saqib, S.
Muhammad, N.
Irfan, M.
Sharif, F.
Bustam, M.A.
Jamal, M.
Khan, M.A.
Waseem, M.A.
Mukhtar, A.
Wajeeh, S.
author_sort Zaman, S.U.
title Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
title_short Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
title_full Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
title_fullStr Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
title_full_unstemmed Fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
title_sort fabrication and performance evaluation of polymeric membrane using blood compatible hydroxyapatite for artificial kidney application
publisher Blackwell Publishing Inc.
publishDate 2021
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85109355892&doi=10.1111%2faor.14020&partnerID=40&md5=f7c98f18db8221016630e18b8b330529
http://eprints.utp.edu.my/23952/
_version_ 1738656545004060672
score 13.211869