Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation

In this paper, a simplified model of an isolated microgrid (IMG) with hybrid photovoltaic (PV)-battery energy storage system (BESS) is discussed. The concept of peak load shaving is also demonstrated. The developed model helps an isolated power system to minimize the demand and maximize the economic...

Full description

Saved in:
Bibliographic Details
Main Authors: Rana, M.M., Romlie, M.F., Abdullah, M.F., Uddin, M., Rahman, M.O.
Format: Article
Published: Accent Social and Welfare Society 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85103413356&doi=10.19101%2fIJATEE.2020.762168&partnerID=40&md5=2bf280d3bbd48c25e8282f4299d82dbd
http://eprints.utp.edu.my/23689/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.23689
record_format eprints
spelling my.utp.eprints.236892021-08-19T08:20:09Z Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation Rana, M.M. Romlie, M.F. Abdullah, M.F. Uddin, M. Rahman, M.O. In this paper, a simplified model of an isolated microgrid (IMG) with hybrid photovoltaic (PV)-battery energy storage system (BESS) is discussed. The concept of peak load shaving is also demonstrated. The developed model helps an isolated power system to minimize the demand and maximize the economic benefit. MATLAB/Simulink tool was used to simulate the electrical circuit of the IMG system. The IMG model contains four sub-systems, namely the PV model, time varying load profile model, BESS model and gas turbine generator (GTG) dispatch model. To evaluate the performance of the developed IMG, a simulation case study was conducted under realistic load conditions of Universiti Teknologi PETRONAS (UTP). Results indicated that simulation illustrates the precise situation of the real-time system, as found in the UTP microgrid. Results also revealed that the concept of peak load shaving broadly illustrated in this study. The implementation of the proposed IMG model may bring economic benefit by minimizing peak load demand. © 2021 Md Masud Rana et al. Accent Social and Welfare Society 2021 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85103413356&doi=10.19101%2fIJATEE.2020.762168&partnerID=40&md5=2bf280d3bbd48c25e8282f4299d82dbd Rana, M.M. and Romlie, M.F. and Abdullah, M.F. and Uddin, M. and Rahman, M.O. (2021) Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation. International Journal of Advanced Technology and Engineering Exploration, 8 (75). pp. 352-361. http://eprints.utp.edu.my/23689/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In this paper, a simplified model of an isolated microgrid (IMG) with hybrid photovoltaic (PV)-battery energy storage system (BESS) is discussed. The concept of peak load shaving is also demonstrated. The developed model helps an isolated power system to minimize the demand and maximize the economic benefit. MATLAB/Simulink tool was used to simulate the electrical circuit of the IMG system. The IMG model contains four sub-systems, namely the PV model, time varying load profile model, BESS model and gas turbine generator (GTG) dispatch model. To evaluate the performance of the developed IMG, a simulation case study was conducted under realistic load conditions of Universiti Teknologi PETRONAS (UTP). Results indicated that simulation illustrates the precise situation of the real-time system, as found in the UTP microgrid. Results also revealed that the concept of peak load shaving broadly illustrated in this study. The implementation of the proposed IMG model may bring economic benefit by minimizing peak load demand. © 2021 Md Masud Rana et al.
format Article
author Rana, M.M.
Romlie, M.F.
Abdullah, M.F.
Uddin, M.
Rahman, M.O.
spellingShingle Rana, M.M.
Romlie, M.F.
Abdullah, M.F.
Uddin, M.
Rahman, M.O.
Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
author_facet Rana, M.M.
Romlie, M.F.
Abdullah, M.F.
Uddin, M.
Rahman, M.O.
author_sort Rana, M.M.
title Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
title_short Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
title_full Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
title_fullStr Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
title_full_unstemmed Modeling of an isolated microgrid with hybrid PV-BESS system for peak load shaving simulation
title_sort modeling of an isolated microgrid with hybrid pv-bess system for peak load shaving simulation
publisher Accent Social and Welfare Society
publishDate 2021
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85103413356&doi=10.19101%2fIJATEE.2020.762168&partnerID=40&md5=2bf280d3bbd48c25e8282f4299d82dbd
http://eprints.utp.edu.my/23689/
_version_ 1738656507707260928
score 13.211869