Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)

Chemical absorption using amines is a suitable method to separate CO2 from CO2 rich natural gas stream. An instantaneous monitoring of CO2 concentration in amine solvent is essential for an efficient chemical absorption process. A spectroscopic technique such as Raman spectroscopy along with multiva...

Full description

Saved in:
Bibliographic Details
Main Authors: Shahid, M.Z., Maulud, A.S., Bustam, M.A.
Format: Article
Published: Elsevier Ltd 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033496020&doi=10.1016%2fj.ijggc.2017.11.006&partnerID=40&md5=17876905dfc1d0b3d56a145a35bddc12
http://eprints.utp.edu.my/20707/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.20707
record_format eprints
spelling my.utp.eprints.207072018-09-25T00:48:42Z Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR) Shahid, M.Z. Maulud, A.S. Bustam, M.A. Chemical absorption using amines is a suitable method to separate CO2 from CO2 rich natural gas stream. An instantaneous monitoring of CO2 concentration in amine solvent is essential for an efficient chemical absorption process. A spectroscopic technique such as Raman spectroscopy along with multivariate modeling is considered as a robust and fast analytical method. It has been applied to monitor CO2 concentration in a chemical absorption process. However, these studies are limited to low CO2 loadings (<0.5 molCO2/molamine) and cannot be extrapolated to high CO2 loading conditions. The evaluation of Raman method at high CO2 loading is essential for the application at high pressure gas streams. In the present study, Raman spectroscopy is non-invasively applied to monitor CO2 concentration in aqueous amines (DEA, MDEA, and their blends) over a wide range of CO2 loadings (0.04�1.3 molCO2/molamine). The partial least square regression (PLSR) calibration models are developed and validated accordingly. The prediction accuracy is reported using determination coefficient (R2) and root mean square error (RMSE). The average validation R2 V and RMSEV for all the studied systems are calculated as 0.94 and 0.064 molCO2/molamine respectively. These values show that Raman spectroscopy with PLSR is a promising technique to monitor CO2 concentration for a wide range of CO2 loading. The improvement in CO2 monitoring is expected to enhance the process efficiency of natural gas processing plants. © 2017 Elsevier Ltd Elsevier Ltd 2018 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033496020&doi=10.1016%2fj.ijggc.2017.11.006&partnerID=40&md5=17876905dfc1d0b3d56a145a35bddc12 Shahid, M.Z. and Maulud, A.S. and Bustam, M.A. (2018) Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR). International Journal of Greenhouse Gas Control, 68 . pp. 42-48. http://eprints.utp.edu.my/20707/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Chemical absorption using amines is a suitable method to separate CO2 from CO2 rich natural gas stream. An instantaneous monitoring of CO2 concentration in amine solvent is essential for an efficient chemical absorption process. A spectroscopic technique such as Raman spectroscopy along with multivariate modeling is considered as a robust and fast analytical method. It has been applied to monitor CO2 concentration in a chemical absorption process. However, these studies are limited to low CO2 loadings (<0.5 molCO2/molamine) and cannot be extrapolated to high CO2 loading conditions. The evaluation of Raman method at high CO2 loading is essential for the application at high pressure gas streams. In the present study, Raman spectroscopy is non-invasively applied to monitor CO2 concentration in aqueous amines (DEA, MDEA, and their blends) over a wide range of CO2 loadings (0.04�1.3 molCO2/molamine). The partial least square regression (PLSR) calibration models are developed and validated accordingly. The prediction accuracy is reported using determination coefficient (R2) and root mean square error (RMSE). The average validation R2 V and RMSEV for all the studied systems are calculated as 0.94 and 0.064 molCO2/molamine respectively. These values show that Raman spectroscopy with PLSR is a promising technique to monitor CO2 concentration for a wide range of CO2 loading. The improvement in CO2 monitoring is expected to enhance the process efficiency of natural gas processing plants. © 2017 Elsevier Ltd
format Article
author Shahid, M.Z.
Maulud, A.S.
Bustam, M.A.
spellingShingle Shahid, M.Z.
Maulud, A.S.
Bustam, M.A.
Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
author_facet Shahid, M.Z.
Maulud, A.S.
Bustam, M.A.
author_sort Shahid, M.Z.
title Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
title_short Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
title_full Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
title_fullStr Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
title_full_unstemmed Non-invasive monitoring of CO2 concentration in aqueous diethanolamine (DEA), methyldiethanolamine (MDEA) and their blends in high CO2 loading region using Raman spectroscopy and partial least square regression (PLSR)
title_sort non-invasive monitoring of co2 concentration in aqueous diethanolamine (dea), methyldiethanolamine (mdea) and their blends in high co2 loading region using raman spectroscopy and partial least square regression (plsr)
publisher Elsevier Ltd
publishDate 2018
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033496020&doi=10.1016%2fj.ijggc.2017.11.006&partnerID=40&md5=17876905dfc1d0b3d56a145a35bddc12
http://eprints.utp.edu.my/20707/
_version_ 1738656221712351232
score 13.223943