Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions
Induction motor is a workhorse in industrial system and it poses a great challenge for the fault detection scheme due to large and complex data processing. Induction motor fault can lead to huge losses and excessive downtimes with regards to maintenance and production. An external fault like unbalan...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024374662&doi=10.1109%2fPECON.2016.7951621&partnerID=40&md5=8594a506057ce656e70f909b7b8bbd21 http://eprints.utp.edu.my/20068/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.20068 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.200682018-04-22T14:39:43Z Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions Sheikh, M.A. Nor, N.M. Ibrahim, T. Induction motor is a workhorse in industrial system and it poses a great challenge for the fault detection scheme due to large and complex data processing. Induction motor fault can lead to huge losses and excessive downtimes with regards to maintenance and production. An external fault like unbalanced voltages supply could be much severed and result in excessive losses, mechanical oscillations, over-voltage, and interference with control electronics. Detection of an abnormality like unbalanced voltage supply is a challenging task in the interaction of electrical motor and the power grid. In this paper, two new methods are presented to diagnose unbalanced voltage supply at the incipient stage. In first method, a new approach is introduced to formulate the total number of winding turns associated with a particular slot. After the formulation, the unbalanced voltage supply was diagnosed through rotor harmonics based on the formulation. While in the other method, the unbalanced asymmetry was detected through signal processing, symbolic time series analysis and D-Markov state transition. The proposed methods also distinguish motor operation under balanced and unbalanced voltage supply. In the proposed work, hardware setup was designed for experimental verification. For validation of the methods, experimental setup was designed to justify and distinguish the motor operating under balanced and unbalanced voltage supply. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024374662&doi=10.1109%2fPECON.2016.7951621&partnerID=40&md5=8594a506057ce656e70f909b7b8bbd21 Sheikh, M.A. and Nor, N.M. and Ibrahim, T. (2017) Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions. PECON 2016 - 2016 IEEE 6th International Conference on Power and Energy, Conference Proceeding . pp. 546-551. http://eprints.utp.edu.my/20068/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Induction motor is a workhorse in industrial system and it poses a great challenge for the fault detection scheme due to large and complex data processing. Induction motor fault can lead to huge losses and excessive downtimes with regards to maintenance and production. An external fault like unbalanced voltages supply could be much severed and result in excessive losses, mechanical oscillations, over-voltage, and interference with control electronics. Detection of an abnormality like unbalanced voltage supply is a challenging task in the interaction of electrical motor and the power grid. In this paper, two new methods are presented to diagnose unbalanced voltage supply at the incipient stage. In first method, a new approach is introduced to formulate the total number of winding turns associated with a particular slot. After the formulation, the unbalanced voltage supply was diagnosed through rotor harmonics based on the formulation. While in the other method, the unbalanced asymmetry was detected through signal processing, symbolic time series analysis and D-Markov state transition. The proposed methods also distinguish motor operation under balanced and unbalanced voltage supply. In the proposed work, hardware setup was designed for experimental verification. For validation of the methods, experimental setup was designed to justify and distinguish the motor operating under balanced and unbalanced voltage supply. © 2016 IEEE. |
format |
Article |
author |
Sheikh, M.A. Nor, N.M. Ibrahim, T. |
spellingShingle |
Sheikh, M.A. Nor, N.M. Ibrahim, T. Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
author_facet |
Sheikh, M.A. Nor, N.M. Ibrahim, T. |
author_sort |
Sheikh, M.A. |
title |
Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
title_short |
Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
title_full |
Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
title_fullStr |
Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
title_full_unstemmed |
Effect of Unbalanced Voltage Supply Diagnosis Through Rotor Harmonics Signature and State Transitions |
title_sort |
effect of unbalanced voltage supply diagnosis through rotor harmonics signature and state transitions |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024374662&doi=10.1109%2fPECON.2016.7951621&partnerID=40&md5=8594a506057ce656e70f909b7b8bbd21 http://eprints.utp.edu.my/20068/ |
_version_ |
1738656159033720832 |
score |
13.211869 |