Hybrid System Automatic Meter Reading
Basically, Tenaga Nasional Berhad (TNB) as the power utility company in Malaysia have two methods to take the metering data from their customers. For their ordinary customers (OPC, Ordinary Power Customer), they used conventional method, by sending meter-readers on monthly basis to do meter readin...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2009
|
Subjects: | |
Online Access: | http://eprints.utp.edu.my/1927/1/ICITE_Paper_%282%29.pdf http://eprints.utp.edu.my/1927/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.1927 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.19272017-01-19T08:25:53Z Hybrid System Automatic Meter Reading Nayan, M Yunus Primacanta, Aryo Handoko TK Electrical engineering. Electronics Nuclear engineering Basically, Tenaga Nasional Berhad (TNB) as the power utility company in Malaysia have two methods to take the metering data from their customers. For their ordinary customers (OPC, Ordinary Power Customer), they used conventional method, by sending meter-readers on monthly basis to do meter reading from meters installed at their customers premises. For large or industrial customers (LPC, Large Power Customer), they used GSM-based Automated Meter Reading (AMR) technology. So GSM module is attached to each LPC’s meter, and data reading can be done automatically without visiting their customer’s sites. For OPC customers, conventional method is facing some issues that need to be improved. In this paper we described the propose hybrid Automated Metering Reading (AMR) system which is a combination of ZigBee and GSM technology. In this propose system ZigBee module will be attached to the meter by using interface board and the data collector will be connected to the central computer by using GSM. The system is suitable with Malaysian condition which already implemented GSM-based AMR in LPC. With this system TNB can save cost in doing meter reading and provide better services to their customers. 2009 Conference or Workshop Item PeerReviewed application/pdf http://eprints.utp.edu.my/1927/1/ICITE_Paper_%282%29.pdf Nayan, M Yunus and Primacanta, Aryo Handoko (2009) Hybrid System Automatic Meter Reading. In: ICITE 2009, Kota Kinabalu Sabah. http://eprints.utp.edu.my/1927/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Nayan, M Yunus Primacanta, Aryo Handoko Hybrid System Automatic Meter Reading |
description |
Basically, Tenaga Nasional Berhad (TNB) as the power utility company in Malaysia have two
methods to take the metering data from their customers. For their ordinary customers (OPC, Ordinary Power
Customer), they used conventional method, by sending meter-readers on monthly basis to do meter reading
from meters installed at their customers premises. For large or industrial customers (LPC, Large Power
Customer), they used GSM-based Automated Meter Reading (AMR) technology. So GSM module is attached
to each LPC’s meter, and data reading can be done automatically without visiting their customer’s sites. For
OPC customers, conventional method is facing some issues that need to be improved. In this paper we
described the propose hybrid Automated Metering Reading (AMR) system which is a combination of ZigBee
and GSM technology. In this propose system ZigBee module will be attached to the meter by using interface
board and the data collector will be connected to the central computer by using GSM. The system is suitable
with Malaysian condition which already implemented GSM-based AMR in LPC. With this system TNB can
save cost in doing meter reading and provide better services to their customers. |
format |
Conference or Workshop Item |
author |
Nayan, M Yunus Primacanta, Aryo Handoko |
author_facet |
Nayan, M Yunus Primacanta, Aryo Handoko |
author_sort |
Nayan, M Yunus |
title |
Hybrid System Automatic Meter Reading |
title_short |
Hybrid System Automatic Meter Reading |
title_full |
Hybrid System Automatic Meter Reading |
title_fullStr |
Hybrid System Automatic Meter Reading |
title_full_unstemmed |
Hybrid System Automatic Meter Reading |
title_sort |
hybrid system automatic meter reading |
publishDate |
2009 |
url |
http://eprints.utp.edu.my/1927/1/ICITE_Paper_%282%29.pdf http://eprints.utp.edu.my/1927/ |
_version_ |
1738655161388105728 |
score |
13.211869 |