Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter

An electrical power system consists of generators, transmission and the distribution network. These networks will deliver power to varying the linear and non-linear loads for consumers. Usually nonlinear electrical devices cause the harmonics distortion of the output sine waveforms of source voltage...

詳細記述

保存先:
書誌詳細
第一著者: Che Ishak, Siti Mastura
フォーマット: 学位論文
言語:English
出版事項: 2021
主題:
オンライン・アクセス:http://eprints.utm.my/id/eprint/99505/1/SitiMasturaIshakMKE2021.pdf
http://eprints.utm.my/id/eprint/99505/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149851
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my.utm.99505
record_format eprints
spelling my.utm.995052023-02-27T08:00:24Z http://eprints.utm.my/id/eprint/99505/ Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter Che Ishak, Siti Mastura TK Electrical engineering. Electronics Nuclear engineering An electrical power system consists of generators, transmission and the distribution network. These networks will deliver power to varying the linear and non-linear loads for consumers. Usually nonlinear electrical devices cause the harmonics distortion of the output sine waveforms of source voltages and currents. Besides, the penetration of Photovoltaic (PV) into distribution increases the harmonics distortion. The equipment of electronic devices will overheat and cause malfunction if it is connected to electrical power system. Removing the harmonic pollution is crucial but it is not an easy task. Therefore, the purpose of this project is to mitigate the harmonic which is generated by Photovoltaic (PV) and nonlinear load using Shunt Active Power Filter (SAPF). This project is designed and simulated by using MATLAB Simulink software as a simulation tool. The analysis of harmonics are carried out using Fast Fourier Transform (FFT) to evaluate the Total Harmonic Distortion (THD) of the nonlinear load and Photovoltaic (PV) with filter and without filter. The results shows that the harmonic distortion is reduced by using the proposed filtering method. 2021 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/99505/1/SitiMasturaIshakMKE2021.pdf Che Ishak, Siti Mastura (2021) Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter. Masters thesis, Universiti Teknologi Malaysia. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149851
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Che Ishak, Siti Mastura
Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
description An electrical power system consists of generators, transmission and the distribution network. These networks will deliver power to varying the linear and non-linear loads for consumers. Usually nonlinear electrical devices cause the harmonics distortion of the output sine waveforms of source voltages and currents. Besides, the penetration of Photovoltaic (PV) into distribution increases the harmonics distortion. The equipment of electronic devices will overheat and cause malfunction if it is connected to electrical power system. Removing the harmonic pollution is crucial but it is not an easy task. Therefore, the purpose of this project is to mitigate the harmonic which is generated by Photovoltaic (PV) and nonlinear load using Shunt Active Power Filter (SAPF). This project is designed and simulated by using MATLAB Simulink software as a simulation tool. The analysis of harmonics are carried out using Fast Fourier Transform (FFT) to evaluate the Total Harmonic Distortion (THD) of the nonlinear load and Photovoltaic (PV) with filter and without filter. The results shows that the harmonic distortion is reduced by using the proposed filtering method.
format Thesis
author Che Ishak, Siti Mastura
author_facet Che Ishak, Siti Mastura
author_sort Che Ishak, Siti Mastura
title Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
title_short Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
title_full Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
title_fullStr Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
title_full_unstemmed Harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
title_sort harmonic mitigation in distribution network resulted from non-linear load and photovoltaic using active filter
publishDate 2021
url http://eprints.utm.my/id/eprint/99505/1/SitiMasturaIshakMKE2021.pdf
http://eprints.utm.my/id/eprint/99505/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149851
_version_ 1758966907252244480
score 13.251813