Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter

In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Impleme...

Full description

Saved in:
Bibliographic Details
Main Authors: Mustafa, Uvais, Arif, M. Saad, Md. Ayob, Shahrin
Format: Article
Published: Inderscience Publishers 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/99430/
http://dx.doi.org/10.1504/IJPELEC.2022.121407
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.99430
record_format eprints
spelling my.utm.994302023-02-27T04:14:16Z http://eprints.utm.my/id/eprint/99430/ Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter Mustafa, Uvais Arif, M. Saad Md. Ayob, Shahrin TK Electrical engineering. Electronics Nuclear engineering In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Implementation feasibility of different PWM techniques and their effect on the performance of the topology has been performed. The PWM switching based on a high frequency is used, as high-frequency PWM technique reduces the THD in the output voltage. The analysis shows that the alternate phase opposite disposition (APOD-PWM) based on a triangular carrier scheme offers the minimum THD of 15.72% for the unity modulation index while operating in an open loop, and in phase disposition (IPD-PWM) triangular carrier scheme offers the minimum common mode current of 222 mA. Also, the output voltage decreases and the fundamental component increases with increment in modulation index is observed. Results obtained show that the topology has low THD as well as common mode current is well within limits for grid-tied applications. Inderscience Publishers 2022 Article PeerReviewed Mustafa, Uvais and Arif, M. Saad and Md. Ayob, Shahrin (2022) Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter. International Journal of Power Electronics, 15 (2). pp. 158-176. ISSN 1756-638X http://dx.doi.org/10.1504/IJPELEC.2022.121407 DOI : 10.1504/IJPELEC.2022.121407
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mustafa, Uvais
Arif, M. Saad
Md. Ayob, Shahrin
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
description In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Implementation feasibility of different PWM techniques and their effect on the performance of the topology has been performed. The PWM switching based on a high frequency is used, as high-frequency PWM technique reduces the THD in the output voltage. The analysis shows that the alternate phase opposite disposition (APOD-PWM) based on a triangular carrier scheme offers the minimum THD of 15.72% for the unity modulation index while operating in an open loop, and in phase disposition (IPD-PWM) triangular carrier scheme offers the minimum common mode current of 222 mA. Also, the output voltage decreases and the fundamental component increases with increment in modulation index is observed. Results obtained show that the topology has low THD as well as common mode current is well within limits for grid-tied applications.
format Article
author Mustafa, Uvais
Arif, M. Saad
Md. Ayob, Shahrin
author_facet Mustafa, Uvais
Arif, M. Saad
Md. Ayob, Shahrin
author_sort Mustafa, Uvais
title Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
title_short Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
title_full Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
title_fullStr Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
title_full_unstemmed Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
title_sort effect of pwm schemes on the performance and common-mode current of the proposed modified seven-level h-bridge inverter
publisher Inderscience Publishers
publishDate 2022
url http://eprints.utm.my/id/eprint/99430/
http://dx.doi.org/10.1504/IJPELEC.2022.121407
_version_ 1758966896896507904
score 13.211869