Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter
In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Impleme...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
Inderscience Publishers
2022
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/99430/ http://dx.doi.org/10.1504/IJPELEC.2022.121407 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.99430 |
---|---|
record_format |
eprints |
spelling |
my.utm.994302023-02-27T04:14:16Z http://eprints.utm.my/id/eprint/99430/ Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter Mustafa, Uvais Arif, M. Saad Md. Ayob, Shahrin TK Electrical engineering. Electronics Nuclear engineering In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Implementation feasibility of different PWM techniques and their effect on the performance of the topology has been performed. The PWM switching based on a high frequency is used, as high-frequency PWM technique reduces the THD in the output voltage. The analysis shows that the alternate phase opposite disposition (APOD-PWM) based on a triangular carrier scheme offers the minimum THD of 15.72% for the unity modulation index while operating in an open loop, and in phase disposition (IPD-PWM) triangular carrier scheme offers the minimum common mode current of 222 mA. Also, the output voltage decreases and the fundamental component increases with increment in modulation index is observed. Results obtained show that the topology has low THD as well as common mode current is well within limits for grid-tied applications. Inderscience Publishers 2022 Article PeerReviewed Mustafa, Uvais and Arif, M. Saad and Md. Ayob, Shahrin (2022) Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter. International Journal of Power Electronics, 15 (2). pp. 158-176. ISSN 1756-638X http://dx.doi.org/10.1504/IJPELEC.2022.121407 DOI : 10.1504/IJPELEC.2022.121407 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Mustafa, Uvais Arif, M. Saad Md. Ayob, Shahrin Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
description |
In this paper, modified H-bridge seven-level inverter topology is proposed. The performance of the proposed topology is evaluated in terms of the THD and the fundamental component of the output voltage for open-loop operation and in terms of common mode current for the connected grid system. Implementation feasibility of different PWM techniques and their effect on the performance of the topology has been performed. The PWM switching based on a high frequency is used, as high-frequency PWM technique reduces the THD in the output voltage. The analysis shows that the alternate phase opposite disposition (APOD-PWM) based on a triangular carrier scheme offers the minimum THD of 15.72% for the unity modulation index while operating in an open loop, and in phase disposition (IPD-PWM) triangular carrier scheme offers the minimum common mode current of 222 mA. Also, the output voltage decreases and the fundamental component increases with increment in modulation index is observed. Results obtained show that the topology has low THD as well as common mode current is well within limits for grid-tied applications. |
format |
Article |
author |
Mustafa, Uvais Arif, M. Saad Md. Ayob, Shahrin |
author_facet |
Mustafa, Uvais Arif, M. Saad Md. Ayob, Shahrin |
author_sort |
Mustafa, Uvais |
title |
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
title_short |
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
title_full |
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
title_fullStr |
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
title_full_unstemmed |
Effect of PWM schemes on the performance and common-mode current of the proposed modified seven-level H-bridge inverter |
title_sort |
effect of pwm schemes on the performance and common-mode current of the proposed modified seven-level h-bridge inverter |
publisher |
Inderscience Publishers |
publishDate |
2022 |
url |
http://eprints.utm.my/id/eprint/99430/ http://dx.doi.org/10.1504/IJPELEC.2022.121407 |
_version_ |
1758966896896507904 |
score |
13.211869 |