Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acce...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2021
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf http://eprints.utm.my/id/eprint/97981/ http://dx.doi.org/10.1088/1755-1315/682/1/012009 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.97981 |
---|---|
record_format |
eprints |
spelling |
my.utm.979812022-11-14T09:27:53Z http://eprints.utm.my/id/eprint/97981/ Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames Koon, F. S. Vafaei, M. Alih, S. C. TA Engineering (General). Civil engineering (General) In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acceleration (PGA) of the selected records was scaled in the range of 0.05g to 0.50g with an increment of 0.05g. Incremental dynamic analysis was employed to determine their inter-story drift demand and capacities. The obtained results indicated that the probability of severe damage to the RC frames increased as the number of stories decreased. It was also observed that the RC frames with inadequate lap splice length exhibited significantly higher probability of collapse when compared with RC frames with adequate lap splice length. 2021 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf Koon, F. S. and Vafaei, M. and Alih, S. C. (2021) Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames. In: 4th National Conference on Wind and Earthquake Engineering, NCWE 2020, 16 - 17 October 2020, Putrajaya, Virtual. http://dx.doi.org/10.1088/1755-1315/682/1/012009 DOI : 10.1109/ACCESS.2021.3105517 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Koon, F. S. Vafaei, M. Alih, S. C. Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
description |
In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acceleration (PGA) of the selected records was scaled in the range of 0.05g to 0.50g with an increment of 0.05g. Incremental dynamic analysis was employed to determine their inter-story drift demand and capacities. The obtained results indicated that the probability of severe damage to the RC frames increased as the number of stories decreased. It was also observed that the RC frames with inadequate lap splice length exhibited significantly higher probability of collapse when compared with RC frames with adequate lap splice length. |
format |
Conference or Workshop Item |
author |
Koon, F. S. Vafaei, M. Alih, S. C. |
author_facet |
Koon, F. S. Vafaei, M. Alih, S. C. |
author_sort |
Koon, F. S. |
title |
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
title_short |
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
title_full |
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
title_fullStr |
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
title_full_unstemmed |
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
title_sort |
effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames |
publishDate |
2021 |
url |
http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf http://eprints.utm.my/id/eprint/97981/ http://dx.doi.org/10.1088/1755-1315/682/1/012009 |
_version_ |
1751536130779512832 |
score |
13.211869 |