Design of biped hip simulator using SolidWorks

The increasing number of people who underwent both hip implant surgery based on World Health Organization (WHO) has received massive attention from researchers lately to develop various types of hip simulators in order to test the hip implant. Various number of hip simulator have been developed with...

Full description

Saved in:
Bibliographic Details
Main Authors: Zainudin, M. R., Yahya, A, Fazli, M. I. M., Syahrom, A., Harun, F. K. C., Nazarudin, M. S.
Format: Conference or Workshop Item
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/97191/1/MRZainudin2017_DesignofBipedHipSimulator.pdf
http://eprints.utm.my/id/eprint/97191/
http://dx.doi.org/10.1088/1742-6596/908/1/012060
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.97191
record_format eprints
spelling my.utm.971912022-09-23T02:55:29Z http://eprints.utm.my/id/eprint/97191/ Design of biped hip simulator using SolidWorks Zainudin, M. R. Yahya, A Fazli, M. I. M. Syahrom, A. Harun, F. K. C. Nazarudin, M. S. TK Electrical engineering. Electronics Nuclear engineering The increasing number of people who underwent both hip implant surgery based on World Health Organization (WHO) has received massive attention from researchers lately to develop various types of hip simulators in order to test the hip implant. Various number of hip simulator have been developed with different functions and capabilities. This paper presents the design development of biped hip simulator using SolidWorks software by taking into consideration some improvement and modifications. The finite element method is used to test the design whether it is safe to be used or not. The biped hip simulator has been successfully designed and ready to be fabricated as the endurance testing shown a positive results. The von Mises stress induced in the material is an alloy steel which is 2,975,862.3 N/m2 lower than the yield strength. Thus, the design is safe to be used as it obey the safety criterion. 2017 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/97191/1/MRZainudin2017_DesignofBipedHipSimulator.pdf Zainudin, M. R. and Yahya, A and Fazli, M. I. M. and Syahrom, A. and Harun, F. K. C. and Nazarudin, M. S. (2017) Design of biped hip simulator using SolidWorks. In: International Conference on Applications and Design in Mechanical Engineering 2017, ICADME 2017, 21 - 22 August 2017, Penang, Malaysia. http://dx.doi.org/10.1088/1742-6596/908/1/012060
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Zainudin, M. R.
Yahya, A
Fazli, M. I. M.
Syahrom, A.
Harun, F. K. C.
Nazarudin, M. S.
Design of biped hip simulator using SolidWorks
description The increasing number of people who underwent both hip implant surgery based on World Health Organization (WHO) has received massive attention from researchers lately to develop various types of hip simulators in order to test the hip implant. Various number of hip simulator have been developed with different functions and capabilities. This paper presents the design development of biped hip simulator using SolidWorks software by taking into consideration some improvement and modifications. The finite element method is used to test the design whether it is safe to be used or not. The biped hip simulator has been successfully designed and ready to be fabricated as the endurance testing shown a positive results. The von Mises stress induced in the material is an alloy steel which is 2,975,862.3 N/m2 lower than the yield strength. Thus, the design is safe to be used as it obey the safety criterion.
format Conference or Workshop Item
author Zainudin, M. R.
Yahya, A
Fazli, M. I. M.
Syahrom, A.
Harun, F. K. C.
Nazarudin, M. S.
author_facet Zainudin, M. R.
Yahya, A
Fazli, M. I. M.
Syahrom, A.
Harun, F. K. C.
Nazarudin, M. S.
author_sort Zainudin, M. R.
title Design of biped hip simulator using SolidWorks
title_short Design of biped hip simulator using SolidWorks
title_full Design of biped hip simulator using SolidWorks
title_fullStr Design of biped hip simulator using SolidWorks
title_full_unstemmed Design of biped hip simulator using SolidWorks
title_sort design of biped hip simulator using solidworks
publishDate 2017
url http://eprints.utm.my/id/eprint/97191/1/MRZainudin2017_DesignofBipedHipSimulator.pdf
http://eprints.utm.my/id/eprint/97191/
http://dx.doi.org/10.1088/1742-6596/908/1/012060
_version_ 1745562349415170048
score 13.211869