Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators

Brushless doubly-fed induction generators have higher reliability, making them an attractive choice for not only offshore applications but also for remote locations. These machines are composed of two back-to-back voltage source converters: the grid side converter and the rotor side converter. The r...

Full description

Saved in:
Bibliographic Details
Main Authors: Memon, Ahsanullah, Mustafa, Mohd. Wazir, Aman, Muhammad Naveed, Ullah, Mukhtar, Kamal, Tariq, Abdul Hafeez, Abdul Hafeez
Format: Article
Language:English
Published: MDPI 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/95354/1/AhsanullahMemon2021_DynamicLowVoltageRidethroughDetection.pdf
http://eprints.utm.my/id/eprint/95354/
http://dx.doi.org/10.3390/en14154461
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.95354
record_format eprints
spelling my.utm.953542022-04-29T22:33:09Z http://eprints.utm.my/id/eprint/95354/ Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators Memon, Ahsanullah Mustafa, Mohd. Wazir Aman, Muhammad Naveed Ullah, Mukhtar Kamal, Tariq Abdul Hafeez, Abdul Hafeez TK Electrical engineering. Electronics Nuclear engineering Brushless doubly-fed induction generators have higher reliability, making them an attractive choice for not only offshore applications but also for remote locations. These machines are composed of two back-to-back voltage source converters: the grid side converter and the rotor side converter. The rotor side converter is typically used for reactive current control of the power winding using the control winding current. A low voltage ride through (LVRT) fault is detected using a hysterisis comparison of the power winding voltage. This approach leads to two problems, firstly, the use of only voltage to detect faults results in erroneous or slow response, and secondly, sub-optimal control of voltage drop because of static reference values for reactive current compensation. This paper solves these problems by using an analytical model of the voltage drop caused by a short circuit. Moreover, using a fuzzy logic controller, the proposed technique employs the voltage frequency in addition to the power winding voltage magnitude to detect LVRT conditions. The analytical model helps in reducing the power winding voltage drop while the fuzzy logic controller leads to better and faster detection of faults, leading to an overall faster response of the system. Simulations in Matlab/Simulink show that the proposed technique can reduce the voltage drop by up to 0.12 p.u. and result in significantly lower transients in the power winding voltage as compared to existing techniques. MDPI 2021-08 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/95354/1/AhsanullahMemon2021_DynamicLowVoltageRidethroughDetection.pdf Memon, Ahsanullah and Mustafa, Mohd. Wazir and Aman, Muhammad Naveed and Ullah, Mukhtar and Kamal, Tariq and Abdul Hafeez, Abdul Hafeez (2021) Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators. Energies, 14 (15). pp. 1-17. ISSN 1996-1073 http://dx.doi.org/10.3390/en14154461 DOI:10.3390/en14154461
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Memon, Ahsanullah
Mustafa, Mohd. Wazir
Aman, Muhammad Naveed
Ullah, Mukhtar
Kamal, Tariq
Abdul Hafeez, Abdul Hafeez
Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
description Brushless doubly-fed induction generators have higher reliability, making them an attractive choice for not only offshore applications but also for remote locations. These machines are composed of two back-to-back voltage source converters: the grid side converter and the rotor side converter. The rotor side converter is typically used for reactive current control of the power winding using the control winding current. A low voltage ride through (LVRT) fault is detected using a hysterisis comparison of the power winding voltage. This approach leads to two problems, firstly, the use of only voltage to detect faults results in erroneous or slow response, and secondly, sub-optimal control of voltage drop because of static reference values for reactive current compensation. This paper solves these problems by using an analytical model of the voltage drop caused by a short circuit. Moreover, using a fuzzy logic controller, the proposed technique employs the voltage frequency in addition to the power winding voltage magnitude to detect LVRT conditions. The analytical model helps in reducing the power winding voltage drop while the fuzzy logic controller leads to better and faster detection of faults, leading to an overall faster response of the system. Simulations in Matlab/Simulink show that the proposed technique can reduce the voltage drop by up to 0.12 p.u. and result in significantly lower transients in the power winding voltage as compared to existing techniques.
format Article
author Memon, Ahsanullah
Mustafa, Mohd. Wazir
Aman, Muhammad Naveed
Ullah, Mukhtar
Kamal, Tariq
Abdul Hafeez, Abdul Hafeez
author_facet Memon, Ahsanullah
Mustafa, Mohd. Wazir
Aman, Muhammad Naveed
Ullah, Mukhtar
Kamal, Tariq
Abdul Hafeez, Abdul Hafeez
author_sort Memon, Ahsanullah
title Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
title_short Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
title_full Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
title_fullStr Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
title_full_unstemmed Dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
title_sort dynamic low voltage ride through detection and mitigation in brushless doubly fed induction generators
publisher MDPI
publishDate 2021
url http://eprints.utm.my/id/eprint/95354/1/AhsanullahMemon2021_DynamicLowVoltageRidethroughDetection.pdf
http://eprints.utm.my/id/eprint/95354/
http://dx.doi.org/10.3390/en14154461
_version_ 1732945462830301184
score 13.211869