Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage

This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a polluted environment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self-t...

Full description

Saved in:
Bibliographic Details
Main Authors: Omran, M. A., Ibrahim, I. I., Ahmad, A. Z., Salem, M., Almelian, M. M., Jusoh, A., Sutikno, T.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/89361/1/AwangJusoh2019_ComparisonsofPIandANNControllers.pdf
http://eprints.utm.my/id/eprint/89361/
http://www.dx.doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.89361
record_format eprints
spelling my.utm.893612021-02-09T04:26:52Z http://eprints.utm.my/id/eprint/89361/ Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage Omran, M. A. Ibrahim, I. I. Ahmad, A. Z. Salem, M. Almelian, M. M. Jusoh, A. Sutikno, T. TK Electrical engineering. Electronics Nuclear engineering This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a polluted environment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self-tuning filter (STF). In order to adjust the dc voltage as a reference value, PI and ANN controllers have been utilized. Moreover, the system has been implemented and simulated in a MATLAB-SIMULINK platform, and selected results are presented. Therefore, the results verified the good dynamic performance, transient stability and strong robustness of the ANN controller. Furthermore, the shunt HAPF with ANN controller has been found to be in agreement with the IEEE 519-1992 standard recommendations on harmonic levels. Institute of Advanced Engineering and Science 2019-09 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/89361/1/AwangJusoh2019_ComparisonsofPIandANNControllers.pdf Omran, M. A. and Ibrahim, I. I. and Ahmad, A. Z. and Salem, M. and Almelian, M. M. and Jusoh, A. and Sutikno, T. (2019) Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage. International Journal of Power Electronics and Drive Systems, 10 (3). pp. 1339-1346. ISSN 2088-8694 http://www.dx.doi.org/10.11591/ijpeds.v10.i3.pp1339-1346 DOI: 10.11591/ijpeds.v10.i3.pp1339-1346
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Omran, M. A.
Ibrahim, I. I.
Ahmad, A. Z.
Salem, M.
Almelian, M. M.
Jusoh, A.
Sutikno, T.
Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
description This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a polluted environment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self-tuning filter (STF). In order to adjust the dc voltage as a reference value, PI and ANN controllers have been utilized. Moreover, the system has been implemented and simulated in a MATLAB-SIMULINK platform, and selected results are presented. Therefore, the results verified the good dynamic performance, transient stability and strong robustness of the ANN controller. Furthermore, the shunt HAPF with ANN controller has been found to be in agreement with the IEEE 519-1992 standard recommendations on harmonic levels.
format Article
author Omran, M. A.
Ibrahim, I. I.
Ahmad, A. Z.
Salem, M.
Almelian, M. M.
Jusoh, A.
Sutikno, T.
author_facet Omran, M. A.
Ibrahim, I. I.
Ahmad, A. Z.
Salem, M.
Almelian, M. M.
Jusoh, A.
Sutikno, T.
author_sort Omran, M. A.
title Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
title_short Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
title_full Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
title_fullStr Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
title_full_unstemmed Comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
title_sort comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
publisher Institute of Advanced Engineering and Science
publishDate 2019
url http://eprints.utm.my/id/eprint/89361/1/AwangJusoh2019_ComparisonsofPIandANNControllers.pdf
http://eprints.utm.my/id/eprint/89361/
http://www.dx.doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
_version_ 1691733094744195072
score 13.211869