Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia

Chemical laboratories safety has become an important issue in Universiti Teknologi Malaysia (UTM), as many accidents occurred in the laboratory such as spillage and explosion. By using USECHH Regulation 2000 as the baseline study, this research was conducted on 18 chemical testing laboratories in UT...

Full description

Saved in:
Bibliographic Details
Main Authors: Aznan, Nursyazwani, Jusoh, Mazura, Zakaria, Zaki Yamani
Format: Article
Language:English
Published: Perintis 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/88300/1/ZakiYamaniZakaria2019_AssessingUSECHHRegulation2000Implementation.pdf
http://eprints.utm.my/id/eprint/88300/
https://perintis.org.my/ejournal/wp-content/uploads/2019/09/3.-ASSESSING-USECHH-REGULATION-2000-IMPLEMENTATION-ON-CHEMICAL-LABORATORIES-A-CASE-STUDY-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.88300
record_format eprints
spelling my.utm.883002020-12-14T23:56:59Z http://eprints.utm.my/id/eprint/88300/ Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia Aznan, Nursyazwani Jusoh, Mazura Zakaria, Zaki Yamani TP Chemical technology Chemical laboratories safety has become an important issue in Universiti Teknologi Malaysia (UTM), as many accidents occurred in the laboratory such as spillage and explosion. By using USECHH Regulation 2000 as the baseline study, this research was conducted on 18 chemical testing laboratories in UTM which are divided into Service Lab, Teaching and Learning Lab and also Research Lab. The enforcement of USECHH Regulation 2000 commonly took place in the industry, however the implementation of it in universities are still not widely accepted. The study was conducted by using audit checklist, questionnaire, on-site observation and interview based on seventeen requirements listed in USECHH Regulation 2000. The methodology was divided into four phases; (1) the quality control; pre-test survey phase, (2) the on-site data gathering information phase, (3) data evaluation phase, and (4) safety plan proposal phase. Among the three types of laboratory, Service Laboratory shows the best result. However one way ANOVA statistical test proved that there are no significant differences between each type of laboratory. The questionnaire results revealed that training, awareness and knowledge, and management support are the critical reasons that contributed to the compliance status of the laboratories. Involvement of students and lecturers, website and system development, and control of procurement are among the critical success factors to improve the enforcement of USECHH Regulation 2000 in the campus. Perintis 2019 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/88300/1/ZakiYamaniZakaria2019_AssessingUSECHHRegulation2000Implementation.pdf Aznan, Nursyazwani and Jusoh, Mazura and Zakaria, Zaki Yamani (2019) Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia. Perintis eJournal, 9 (1). pp. 30-47. ISSN 2232-0725 https://perintis.org.my/ejournal/wp-content/uploads/2019/09/3.-ASSESSING-USECHH-REGULATION-2000-IMPLEMENTATION-ON-CHEMICAL-LABORATORIES-A-CASE-STUDY-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Aznan, Nursyazwani
Jusoh, Mazura
Zakaria, Zaki Yamani
Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
description Chemical laboratories safety has become an important issue in Universiti Teknologi Malaysia (UTM), as many accidents occurred in the laboratory such as spillage and explosion. By using USECHH Regulation 2000 as the baseline study, this research was conducted on 18 chemical testing laboratories in UTM which are divided into Service Lab, Teaching and Learning Lab and also Research Lab. The enforcement of USECHH Regulation 2000 commonly took place in the industry, however the implementation of it in universities are still not widely accepted. The study was conducted by using audit checklist, questionnaire, on-site observation and interview based on seventeen requirements listed in USECHH Regulation 2000. The methodology was divided into four phases; (1) the quality control; pre-test survey phase, (2) the on-site data gathering information phase, (3) data evaluation phase, and (4) safety plan proposal phase. Among the three types of laboratory, Service Laboratory shows the best result. However one way ANOVA statistical test proved that there are no significant differences between each type of laboratory. The questionnaire results revealed that training, awareness and knowledge, and management support are the critical reasons that contributed to the compliance status of the laboratories. Involvement of students and lecturers, website and system development, and control of procurement are among the critical success factors to improve the enforcement of USECHH Regulation 2000 in the campus.
format Article
author Aznan, Nursyazwani
Jusoh, Mazura
Zakaria, Zaki Yamani
author_facet Aznan, Nursyazwani
Jusoh, Mazura
Zakaria, Zaki Yamani
author_sort Aznan, Nursyazwani
title Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
title_short Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
title_full Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
title_fullStr Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
title_full_unstemmed Assessing USECHH regulation 2000 implementation on chemical laboratories: a case study of Universiti Teknologi Malaysia
title_sort assessing usechh regulation 2000 implementation on chemical laboratories: a case study of universiti teknologi malaysia
publisher Perintis
publishDate 2019
url http://eprints.utm.my/id/eprint/88300/1/ZakiYamaniZakaria2019_AssessingUSECHHRegulation2000Implementation.pdf
http://eprints.utm.my/id/eprint/88300/
https://perintis.org.my/ejournal/wp-content/uploads/2019/09/3.-ASSESSING-USECHH-REGULATION-2000-IMPLEMENTATION-ON-CHEMICAL-LABORATORIES-A-CASE-STUDY-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
_version_ 1687393553006723072
score 13.211869