Development of automatic mixing process for fertigation system in rock melon cultivation

This work proposed an automatic mixing system of nutrient solution for rock melon fertigation according to the required electrical conductivity (EC) level. Compared to the manual practice, this automatic system will ensure continuous supply of mixed nutrient solution without the need to daily check...

Full description

Saved in:
Bibliographic Details
Main Authors: Abd. Rahman, M. K. I., Buyamin, S., Abidin, M. S. Z., Mokji, M. M.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79722/1/SalindaBuyamin2018_DevelopmentofAutomaticMixingProces.pdf
http://eprints.utm.my/id/eprint/79722/
http://dx.doi.org/10.11591/ijece.v8i3.pp1913-1919
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.79722
record_format eprints
spelling my.utm.797222019-01-28T06:37:51Z http://eprints.utm.my/id/eprint/79722/ Development of automatic mixing process for fertigation system in rock melon cultivation Abd. Rahman, M. K. I. Buyamin, S. Abidin, M. S. Z. Mokji, M. M. TK Electrical engineering. Electronics Nuclear engineering This work proposed an automatic mixing system of nutrient solution for rock melon fertigation according to the required electrical conductivity (EC) level. Compared to the manual practice, this automatic system will ensure continuous supply of mixed nutrient solution without the need to daily check and mix new nutrient. Thus, this easy to use and low cost automatic system will reduce the burden of the farmers. This system uses an EC sensor to automatically check the concentration level of the mixed nutrient solution. Other than that, the system only consists of electronic pumps for mixing process and an Arduino board as the controller. The controller will monitor the EC level and run the mixing process when the EC level is below the required level. By calibrating the EC sensors, the test shows that the automatic mixing system is able to accurately keep the mixed nutrient solution concentration in a 400 L mixing reservoir at several required levels. Institute of Advanced Engineering and Science 2018 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79722/1/SalindaBuyamin2018_DevelopmentofAutomaticMixingProces.pdf Abd. Rahman, M. K. I. and Buyamin, S. and Abidin, M. S. Z. and Mokji, M. M. (2018) Development of automatic mixing process for fertigation system in rock melon cultivation. International Journal of Electrical and Computer Engineering, 8 (3). pp. 1913-1919. ISSN 2088-8708 http://dx.doi.org/10.11591/ijece.v8i3.pp1913-1919 DOI:10.11591/ijece.v8i3.pp1913-1919
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abd. Rahman, M. K. I.
Buyamin, S.
Abidin, M. S. Z.
Mokji, M. M.
Development of automatic mixing process for fertigation system in rock melon cultivation
description This work proposed an automatic mixing system of nutrient solution for rock melon fertigation according to the required electrical conductivity (EC) level. Compared to the manual practice, this automatic system will ensure continuous supply of mixed nutrient solution without the need to daily check and mix new nutrient. Thus, this easy to use and low cost automatic system will reduce the burden of the farmers. This system uses an EC sensor to automatically check the concentration level of the mixed nutrient solution. Other than that, the system only consists of electronic pumps for mixing process and an Arduino board as the controller. The controller will monitor the EC level and run the mixing process when the EC level is below the required level. By calibrating the EC sensors, the test shows that the automatic mixing system is able to accurately keep the mixed nutrient solution concentration in a 400 L mixing reservoir at several required levels.
format Article
author Abd. Rahman, M. K. I.
Buyamin, S.
Abidin, M. S. Z.
Mokji, M. M.
author_facet Abd. Rahman, M. K. I.
Buyamin, S.
Abidin, M. S. Z.
Mokji, M. M.
author_sort Abd. Rahman, M. K. I.
title Development of automatic mixing process for fertigation system in rock melon cultivation
title_short Development of automatic mixing process for fertigation system in rock melon cultivation
title_full Development of automatic mixing process for fertigation system in rock melon cultivation
title_fullStr Development of automatic mixing process for fertigation system in rock melon cultivation
title_full_unstemmed Development of automatic mixing process for fertigation system in rock melon cultivation
title_sort development of automatic mixing process for fertigation system in rock melon cultivation
publisher Institute of Advanced Engineering and Science
publishDate 2018
url http://eprints.utm.my/id/eprint/79722/1/SalindaBuyamin2018_DevelopmentofAutomaticMixingProces.pdf
http://eprints.utm.my/id/eprint/79722/
http://dx.doi.org/10.11591/ijece.v8i3.pp1913-1919
_version_ 1643658274321465344
score 13.211869