Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework
In this paper, a conceptual framework for a non destructive testing to check defect on composite material using parallel plate electrical capacitance tomography is being proposed. At the early stage, the possibility of using this method is being simulated using Comsol Multiphysic software. The simul...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/76746/1/RuzairiAbdulRahim2017_DesignofNonDestructiveTestingonComposite.pdf http://eprints.utm.my/id/eprint/76746/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85025096890&doi=10.11113%2fjt.v79.11286&partnerID=40&md5=6a03fc94d3997fc2bcbc2f8228e9775c |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.76746 |
---|---|
record_format |
eprints |
spelling |
my.utm.767462018-05-31T09:28:09Z http://eprints.utm.my/id/eprint/76746/ Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework Abd. Rashid, W. N. Mohamad, E. J. Abdul Rahim, R. Subki, A. S. R. Ahood, A. L. Kadmin, A. F. Naim Mohayat, M. H. Ahmad, M. Mohd. Tah, M. A. TK Electrical engineering. Electronics Nuclear engineering In this paper, a conceptual framework for a non destructive testing to check defect on composite material using parallel plate electrical capacitance tomography is being proposed. At the early stage, the possibility of using this method is being simulated using Comsol Multiphysic software. The simulation process has shown promising results to make this concept works. When a dielectric material is placed between the parallel plates, the permittivity distribution can be observed. As the number of electrodes of the sensor are increased from 2 to 8 electrodes, the capacitance value increase from 2.0131e-11-2.3532e-14i F to 5.2474e-11-3.0756e-13i F. Furthermore, there are significant results when the size and the permittivity of the object are varies. Penerbit UTM Press 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/76746/1/RuzairiAbdulRahim2017_DesignofNonDestructiveTestingonComposite.pdf Abd. Rashid, W. N. and Mohamad, E. J. and Abdul Rahim, R. and Subki, A. S. R. and Ahood, A. L. and Kadmin, A. F. and Naim Mohayat, M. H. and Ahmad, M. and Mohd. Tah, M. A. (2017) Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework. Jurnal Teknologi, 79 (5-2). pp. 71-76. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85025096890&doi=10.11113%2fjt.v79.11286&partnerID=40&md5=6a03fc94d3997fc2bcbc2f8228e9775c DOI:10.11113/jt.v79.11286 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Abd. Rashid, W. N. Mohamad, E. J. Abdul Rahim, R. Subki, A. S. R. Ahood, A. L. Kadmin, A. F. Naim Mohayat, M. H. Ahmad, M. Mohd. Tah, M. A. Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
description |
In this paper, a conceptual framework for a non destructive testing to check defect on composite material using parallel plate electrical capacitance tomography is being proposed. At the early stage, the possibility of using this method is being simulated using Comsol Multiphysic software. The simulation process has shown promising results to make this concept works. When a dielectric material is placed between the parallel plates, the permittivity distribution can be observed. As the number of electrodes of the sensor are increased from 2 to 8 electrodes, the capacitance value increase from 2.0131e-11-2.3532e-14i F to 5.2474e-11-3.0756e-13i F. Furthermore, there are significant results when the size and the permittivity of the object are varies. |
format |
Article |
author |
Abd. Rashid, W. N. Mohamad, E. J. Abdul Rahim, R. Subki, A. S. R. Ahood, A. L. Kadmin, A. F. Naim Mohayat, M. H. Ahmad, M. Mohd. Tah, M. A. |
author_facet |
Abd. Rashid, W. N. Mohamad, E. J. Abdul Rahim, R. Subki, A. S. R. Ahood, A. L. Kadmin, A. F. Naim Mohayat, M. H. Ahmad, M. Mohd. Tah, M. A. |
author_sort |
Abd. Rashid, W. N. |
title |
Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
title_short |
Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
title_full |
Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
title_fullStr |
Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
title_full_unstemmed |
Design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
title_sort |
design of non destructive testing on composite material using parallel plate electrical capacitance tomography: a conceptual framework |
publisher |
Penerbit UTM Press |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/76746/1/RuzairiAbdulRahim2017_DesignofNonDestructiveTestingonComposite.pdf http://eprints.utm.my/id/eprint/76746/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85025096890&doi=10.11113%2fjt.v79.11286&partnerID=40&md5=6a03fc94d3997fc2bcbc2f8228e9775c |
_version_ |
1643657398222585856 |
score |
13.211869 |