An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf http://eprints.utm.my/id/eprint/74901/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.74901 |
---|---|
record_format |
eprints |
spelling |
my.utm.749012018-03-22T10:57:10Z http://eprints.utm.my/id/eprint/74901/ An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions Naderipour, A. Zin, A. A. M. Habibuddin, M. H. B. Miveh, M. R. Guerrero, J. M. TK Electrical engineering. Electronics Nuclear engineering In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. © 2017 Naderipour et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Public Library of Science 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf Naderipour, A. and Zin, A. A. M. and Habibuddin, M. H. B. and Miveh, M. R. and Guerrero, J. M. (2017) An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions. PLoS ONE, 12 (2). ISSN 1932-6203 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Naderipour, A. Zin, A. A. M. Habibuddin, M. H. B. Miveh, M. R. Guerrero, J. M. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
description |
In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. © 2017 Naderipour et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
format |
Article |
author |
Naderipour, A. Zin, A. A. M. Habibuddin, M. H. B. Miveh, M. R. Guerrero, J. M. |
author_facet |
Naderipour, A. Zin, A. A. M. Habibuddin, M. H. B. Miveh, M. R. Guerrero, J. M. |
author_sort |
Naderipour, A. |
title |
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_short |
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_full |
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_fullStr |
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_full_unstemmed |
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
title_sort |
improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions |
publisher |
Public Library of Science |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf http://eprints.utm.my/id/eprint/74901/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7 |
_version_ |
1643656966262751232 |
score |
13.211869 |