An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....

Full description

Saved in:
Bibliographic Details
Main Authors: Naderipour, A., Zin, A. A. M., Habibuddin, M. H. B., Miveh, M. R., Guerrero, J. M.
Format: Article
Language:English
Published: Public Library of Science 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf
http://eprints.utm.my/id/eprint/74901/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.74901
record_format eprints
spelling my.utm.749012018-03-22T10:57:10Z http://eprints.utm.my/id/eprint/74901/ An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions Naderipour, A. Zin, A. A. M. Habibuddin, M. H. B. Miveh, M. R. Guerrero, J. M. TK Electrical engineering. Electronics Nuclear engineering In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. © 2017 Naderipour et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Public Library of Science 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf Naderipour, A. and Zin, A. A. M. and Habibuddin, M. H. B. and Miveh, M. R. and Guerrero, J. M. (2017) An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions. PLoS ONE, 12 (2). ISSN 1932-6203 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Naderipour, A.
Zin, A. A. M.
Habibuddin, M. H. B.
Miveh, M. R.
Guerrero, J. M.
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
description In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. © 2017 Naderipour et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
format Article
author Naderipour, A.
Zin, A. A. M.
Habibuddin, M. H. B.
Miveh, M. R.
Guerrero, J. M.
author_facet Naderipour, A.
Zin, A. A. M.
Habibuddin, M. H. B.
Miveh, M. R.
Guerrero, J. M.
author_sort Naderipour, A.
title An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_short An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_full An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_fullStr An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_full_unstemmed An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
title_sort improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
publisher Public Library of Science
publishDate 2017
url http://eprints.utm.my/id/eprint/74901/1/AbdullahAsuhaimi_AnImprovedSynchronousReferenceFrame.pdf
http://eprints.utm.my/id/eprint/74901/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012225104&doi=10.1371%2fjournal.pone.0164856&partnerID=40&md5=9c1c34c70909412a52ab1e0c4520e6c7
_version_ 1643656966262751232
score 13.211869