Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy
Cathodic arc physical vapor deposition (CAPVD) is one of the promising techniques that have a potential to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this method emits microdroplets which have the possible detrimental effect on the...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/74380/1/SIzman2016_InfluenceofNitrogenFlowRate.pdf http://eprints.utm.my/id/eprint/74380/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971408210&doi=10.11113%2fjt.v78.8825&partnerID=40&md5=98998184b4cf50b75d1f94d2b4927399 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.74380 |
---|---|
record_format |
eprints |
spelling |
my.utm.743802017-11-23T01:37:10Z http://eprints.utm.my/id/eprint/74380/ Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy Shah, A. Izman, S. Hassan, M. A. TP Chemical technology Cathodic arc physical vapor deposition (CAPVD) is one of the promising techniques that have a potential to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this method emits microdroplets which have the possible detrimental effect on the coating performance. Past studies indicated that micro droplets can be controlled through proper deposition parameters. In the present work, an attempt was made to study the effect of nitrogen gas flow rates (100 to 300 sccm) on TiN coating of the Ti-13Zr-13Nb biomedical alloy. Scanning electron microscopy (SEM) was used to evaluate surface morphology and coating thickness while crystal phase of the coated substrates was determined using X-Ray Diffraction (XRD). Image analysis software was employed to quantify microdroplets counts. Results show that higher nitrogen gas flow rate able to decrease a significant amount of microdroplets and concurrently increase the thickness of TiN coating. A mixed crystal planes of (111) and (220) are obtained on the coated substrates at this setting which exhibits denser structure with higher adhesion strength as compared to substrates coated at the lower N2 gas flow rate. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/74380/1/SIzman2016_InfluenceofNitrogenFlowRate.pdf Shah, A. and Izman, S. and Hassan, M. A. (2016) Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy. Jurnal Teknologi, 78 (5-10). pp. 6-10. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971408210&doi=10.11113%2fjt.v78.8825&partnerID=40&md5=98998184b4cf50b75d1f94d2b4927399 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Shah, A. Izman, S. Hassan, M. A. Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
description |
Cathodic arc physical vapor deposition (CAPVD) is one of the promising techniques that have a potential to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this method emits microdroplets which have the possible detrimental effect on the coating performance. Past studies indicated that micro droplets can be controlled through proper deposition parameters. In the present work, an attempt was made to study the effect of nitrogen gas flow rates (100 to 300 sccm) on TiN coating of the Ti-13Zr-13Nb biomedical alloy. Scanning electron microscopy (SEM) was used to evaluate surface morphology and coating thickness while crystal phase of the coated substrates was determined using X-Ray Diffraction (XRD). Image analysis software was employed to quantify microdroplets counts. Results show that higher nitrogen gas flow rate able to decrease a significant amount of microdroplets and concurrently increase the thickness of TiN coating. A mixed crystal planes of (111) and (220) are obtained on the coated substrates at this setting which exhibits denser structure with higher adhesion strength as compared to substrates coated at the lower N2 gas flow rate. |
format |
Article |
author |
Shah, A. Izman, S. Hassan, M. A. |
author_facet |
Shah, A. Izman, S. Hassan, M. A. |
author_sort |
Shah, A. |
title |
Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
title_short |
Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
title_full |
Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
title_fullStr |
Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
title_full_unstemmed |
Influence of nitrogen flow rate in reducing tin microdroplets on biomedical TI-13ZR-13NB alloy |
title_sort |
influence of nitrogen flow rate in reducing tin microdroplets on biomedical ti-13zr-13nb alloy |
publisher |
Penerbit UTM Press |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/74380/1/SIzman2016_InfluenceofNitrogenFlowRate.pdf http://eprints.utm.my/id/eprint/74380/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971408210&doi=10.11113%2fjt.v78.8825&partnerID=40&md5=98998184b4cf50b75d1f94d2b4927399 |
_version_ |
1643656846395834368 |
score |
13.211869 |