Fabrication of a composite modified glassy carbon electrode: a highly selective, sensitive and rapid electrochemical sensor for silver ion detection in river water samples

In this study, a glassy carbon electrode (GCE) was modified with multi-walled carbon nanotubes (MWCNTs), 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim]PF6), N,N′-bis(2-hydroxyacetophenone)ethylenediamine (BZE) and Nafion to form a MWCNT-BZE-[bmim]PF6-Nafion-GCE. The electrochemical behaviou...

Full description

Saved in:
Bibliographic Details
Main Authors: Azhari, S., Sathishkumar, P., Ahamad, R., Ahmad, F., Yusoff, A. R. M.
Format: Article
Published: Royal Society of Chemistry 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/72293/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84978745361&doi=10.1039%2fc6ay01336h&partnerID=40&md5=fa37b3ec682c734d24111b2a75a7e63e
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this study, a glassy carbon electrode (GCE) was modified with multi-walled carbon nanotubes (MWCNTs), 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim]PF6), N,N′-bis(2-hydroxyacetophenone)ethylenediamine (BZE) and Nafion to form a MWCNT-BZE-[bmim]PF6-Nafion-GCE. The electrochemical behaviour of the modified electrode with respect to silver (Ag(i)) ion detection was studied by cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DPASV). Furthermore, the experimental parameters including the pH value of Britton-Robinson Buffer (BRB), Nafion, MWCNTs, BZE and ([bmim]PF6) concentrations and the deposition potential and time were optimized. The detection limit of the modified electrode for the Ag(i) ion was found to be 70 ng L-1 (6.49 × 10-10 mol L-1). Repetitive measurements revealed good reproducibility with a relative standard deviation (RSD) value of 0.4%. The system performance of the modified electrode was highly satisfactory and the recoveries for river water samples were found to be 96-121%. This study proved that the MWCNT-BZE-[bmim]PF6-Nafion-GCE is a highly selective and sensitive modified electrode for the detection of the Ag(i) ion in river water samples with good recovery value.