Effect of stressed-skin action on optimal design of cold-formed steel square and rectangular-shaped portal frame buildings
Cold-formed steel (CFS) portal frames can be a viable alternative to conventional hot-rolled steel portal frames. They are commonly used for low-rise commercial, light industrial and agricultural buildings. In this paper, the effect of stressed-skin action on the optimum design of CFS portal frames...
Saved in:
Main Authors: | Wrzesien, Andrzej M., Phan, Duoc T., Lim, James B. P., Lau, Hieng Ho, Hajirasouliha, Iman, Tan, Cher Siang |
---|---|
Format: | Article |
Published: |
Korean Society of Steel Construction
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/69302/ http://dx.doi.org/10.1007/s13296-016-6004-2 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
In-plane sway behaviour of slender cold-formed steel bolted frames
by: Yeong, Huei Lee, et al.
Published: (2017) -
Structural Analysis And Design Of Steel-Framed House With Cold-Formed And Hot-Finished Rectangular Hollow Section
by: Naaim, Nurfarhah
Published: (2019) -
Semi-rigid composite beam-to-column joints for cold-formed steel frames: experimental and numerical study.
by: Amsyar, Faisal, et al.
Published: (2023) -
Semi‑rigid Composite Beam‑to‑column Joints for Cold‑formed Steel Frames : Experimental and Numerical Study
by: Faisal, Amsyar, et al.
Published: (2023) -
Flexural behaviour of reinforced slab panel system with embedded cold-formed steel frames as reinforcement
by: Cher, Siang Tan, et al.
Published: (2015)