Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology

Cobalt–chromium (Co–Cr)-based alloys have been used extensively as medical implants, but the ion release and the corrosion products can affect their mechanical integrity and biocompatibility. One of the solutions is to surface coat the substrate with hydroxyapatite via electrophoretic deposition tec...

詳細記述

保存先:
書誌詳細
主要な著者: Shirdar, Mostafa Rezazadeh, Izman, Sudin, Taheri, Mohammad Mahdi, Assadian, Mahtab, Abdul Kadir, Mohammed Rafiq
フォーマット: 論文
出版事項: Springer Verlag 2016
主題:
オンライン・アクセス:http://eprints.utm.my/id/eprint/69271/
http://dx.doi.org/10.1007/s13369-015-1700-3
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my.utm.69271
record_format eprints
spelling my.utm.692712017-11-22T00:45:14Z http://eprints.utm.my/id/eprint/69271/ Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology Shirdar, Mostafa Rezazadeh Izman, Sudin Taheri, Mohammad Mahdi Assadian, Mahtab Abdul Kadir, Mohammed Rafiq TJ Mechanical engineering and machinery Cobalt–chromium (Co–Cr)-based alloys have been used extensively as medical implants, but the ion release and the corrosion products can affect their mechanical integrity and biocompatibility. One of the solutions is to surface coat the substrate with hydroxyapatite via electrophoretic deposition technique. Two variables—pH of electrolyte and current density—were used to examine the electrochemical behavior of the coated sample. An experimental strategy was developed based on the response surface methodology together with the analysis of variance to verify the precision of the mathematical models and their relative parameters. Close agreement was observed between the predicted models and the experimental results. The pH value of electrolyte was a more significant factor than current density in increasing the corrosion potential (Ecorr) of the substrate. The maximum Ecorr was obtained with a current density of 12 mA cm−2 and a pH value of 4.71. Springer Verlag 2016 Article PeerReviewed Shirdar, Mostafa Rezazadeh and Izman, Sudin and Taheri, Mohammad Mahdi and Assadian, Mahtab and Abdul Kadir, Mohammed Rafiq (2016) Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology. Arabian Journal for Science And Engineering, 41 (2). pp. 591-598. ISSN 1319-8025 http://dx.doi.org/10.1007/s13369-015-1700-3 DOI:10.1007/s13369-015-1700-3
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Shirdar, Mostafa Rezazadeh
Izman, Sudin
Taheri, Mohammad Mahdi
Assadian, Mahtab
Abdul Kadir, Mohammed Rafiq
Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
description Cobalt–chromium (Co–Cr)-based alloys have been used extensively as medical implants, but the ion release and the corrosion products can affect their mechanical integrity and biocompatibility. One of the solutions is to surface coat the substrate with hydroxyapatite via electrophoretic deposition technique. Two variables—pH of electrolyte and current density—were used to examine the electrochemical behavior of the coated sample. An experimental strategy was developed based on the response surface methodology together with the analysis of variance to verify the precision of the mathematical models and their relative parameters. Close agreement was observed between the predicted models and the experimental results. The pH value of electrolyte was a more significant factor than current density in increasing the corrosion potential (Ecorr) of the substrate. The maximum Ecorr was obtained with a current density of 12 mA cm−2 and a pH value of 4.71.
format Article
author Shirdar, Mostafa Rezazadeh
Izman, Sudin
Taheri, Mohammad Mahdi
Assadian, Mahtab
Abdul Kadir, Mohammed Rafiq
author_facet Shirdar, Mostafa Rezazadeh
Izman, Sudin
Taheri, Mohammad Mahdi
Assadian, Mahtab
Abdul Kadir, Mohammed Rafiq
author_sort Shirdar, Mostafa Rezazadeh
title Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
title_short Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
title_full Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
title_fullStr Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
title_full_unstemmed Effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
title_sort effect of electrophoretic deposition parameters on the corrosion behavior of hydroxyapatite-coated cobalt-chromium using response surface methodology
publisher Springer Verlag
publishDate 2016
url http://eprints.utm.my/id/eprint/69271/
http://dx.doi.org/10.1007/s13369-015-1700-3
_version_ 1643656046202322944
score 13.251813