Design of heat exchanger network in olefin unit of oil refinery
The main purpose of this study is to propose a new design of oil refinery that shall be more optimum and efficient. In designing the optimum system, there are four steps to be done which are analysis of the existence exchangers, fixing the bad exchangers, replacing new exchangers and doing final cha...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/63301/ http://www.akademiabaru.com/wvcasea2015/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.63301 |
---|---|
record_format |
eprints |
spelling |
my.utm.633012017-08-21T08:50:21Z http://eprints.utm.my/id/eprint/63301/ Design of heat exchanger network in olefin unit of oil refinery Mohammad, R. Sharifi, F. Sharifi, D. Othman, Norazli Kadir, Z. A. TJ Mechanical engineering and machinery The main purpose of this study is to propose a new design of oil refinery that shall be more optimum and efficient. In designing the optimum system, there are four steps to be done which are analysis of the existence exchangers, fixing the bad exchangers, replacing new exchangers and doing final changes on the refinery. This research is to analyse on an Iranian refinery (Isfahan refinery) and investigate all the exchanger conditions and locations which need to be fixed or changed. As a results, none of the flows has been separated and the change that has been done is very minimum. The temperature on the main tower has been reduced almost to 52˚C, the cooling system numbers 108, 123 and 161 have been removed from the network and the temperature on cooler number 101 and water cooler number 172 has been reduced. Seven new exchangers with the surface temperature of 1807M2, have been installed and 2 new shells have been added to exchanger 155. The position of this exchanger has been changed and has been moved in between exchangers’ numbers 157 and 158. All new exchangers also have been installed in the old place of exchanger number 155. 2015 Conference or Workshop Item PeerReviewed Mohammad, R. and Sharifi, F. and Sharifi, D. and Othman, Norazli and Kadir, Z. A. (2015) Design of heat exchanger network in olefin unit of oil refinery. In: Proceedings of the 4th World Virtual Conference on Applied Sciences & Engineering Applications, 28-30 Nov 2015, Kuala Lumpur, Malaysia. http://www.akademiabaru.com/wvcasea2015/ |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Mohammad, R. Sharifi, F. Sharifi, D. Othman, Norazli Kadir, Z. A. Design of heat exchanger network in olefin unit of oil refinery |
description |
The main purpose of this study is to propose a new design of oil refinery that shall be more optimum and efficient. In designing the optimum system, there are four steps to be done which are analysis of the existence exchangers, fixing the bad exchangers, replacing new exchangers and doing final changes on the refinery. This research is to analyse on an Iranian refinery (Isfahan refinery) and investigate all the exchanger conditions and locations which need to be fixed or changed. As a results, none of the flows has been separated and the change that has been done is very minimum. The temperature on the main tower has been reduced almost to 52˚C, the cooling system numbers 108, 123 and 161 have been removed from the network and the temperature on cooler number 101 and water cooler number 172 has been reduced. Seven new exchangers with the surface temperature of 1807M2, have been installed and 2 new shells have been added to exchanger 155. The position of this exchanger has been changed and has been moved in between exchangers’ numbers 157 and 158. All new exchangers also have been installed in the old place of exchanger number 155. |
format |
Conference or Workshop Item |
author |
Mohammad, R. Sharifi, F. Sharifi, D. Othman, Norazli Kadir, Z. A. |
author_facet |
Mohammad, R. Sharifi, F. Sharifi, D. Othman, Norazli Kadir, Z. A. |
author_sort |
Mohammad, R. |
title |
Design of heat exchanger network in olefin unit of oil refinery |
title_short |
Design of heat exchanger network in olefin unit of oil refinery |
title_full |
Design of heat exchanger network in olefin unit of oil refinery |
title_fullStr |
Design of heat exchanger network in olefin unit of oil refinery |
title_full_unstemmed |
Design of heat exchanger network in olefin unit of oil refinery |
title_sort |
design of heat exchanger network in olefin unit of oil refinery |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/63301/ http://www.akademiabaru.com/wvcasea2015/ |
_version_ |
1643655680259784704 |
score |
13.211869 |