Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter
As the natural behavior of energy source and design characteristic, the current generated by a grid-interactive PV-inverter may contain harmonics. This distortion component will be carried on from the PV-inverter during injection power into the grid. Excessive harmonics in a grid will lead to a vari...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Elsevier Ltd.
2014
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/62422/ http://dx.doi.org/10.1016/j.enconman.2014.05.031 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.62422 |
---|---|
record_format |
eprints |
spelling |
my.utm.624222017-06-14T01:31:16Z http://eprints.utm.my/id/eprint/62422/ Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter Jusoh, Awang Hamid, Muhammad Imran TK Electrical engineering. Electronics Nuclear engineering As the natural behavior of energy source and design characteristic, the current generated by a grid-interactive PV-inverter may contain harmonics. This distortion component will be carried on from the PV-inverter during injection power into the grid. Excessive harmonics in a grid will lead to a variety of power quality problems. This paper presents a distortion reduction scheme, utilizing a fed forward single-phase, generation-side power conditioner with a structure that can be expanded for use in a three-phase system and can work independently under imbalanced condition. Conditioner is placed in parallel with the photovoltaic plant and it functions to compensate the plant's output current distortion, so that the total current flow to the grid is sinusoidal. This method also includes the implementation of a simpler control system for the conditioner, which consists of a combination of distortion current extraction, synchronization and a current control system, and realized through a TMS320F28335: a 150 MHz floating point DSP controller. Testing of the conditioner prototype, which was conducted on a real operation of a PV plant, showed that the scheme worked effectively within the overall operation range of the PV plant. This paper also discusses the potential of utility factor improvement of the PV-inverter and plant due to implementation of conditioner in the scheme. Elsevier Ltd. 2014 Article PeerReviewed Jusoh, Awang and Hamid, Muhammad Imran (2014) Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter. Energy Conversion and Management, 85 . pp. 212-226. ISSN 0196-8904 http://dx.doi.org/10.1016/j.enconman.2014.05.031 DOI:10.1016/j.enconman.2014.05.031 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Jusoh, Awang Hamid, Muhammad Imran Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
description |
As the natural behavior of energy source and design characteristic, the current generated by a grid-interactive PV-inverter may contain harmonics. This distortion component will be carried on from the PV-inverter during injection power into the grid. Excessive harmonics in a grid will lead to a variety of power quality problems. This paper presents a distortion reduction scheme, utilizing a fed forward single-phase, generation-side power conditioner with a structure that can be expanded for use in a three-phase system and can work independently under imbalanced condition. Conditioner is placed in parallel with the photovoltaic plant and it functions to compensate the plant's output current distortion, so that the total current flow to the grid is sinusoidal. This method also includes the implementation of a simpler control system for the conditioner, which consists of a combination of distortion current extraction, synchronization and a current control system, and realized through a TMS320F28335: a 150 MHz floating point DSP controller. Testing of the conditioner prototype, which was conducted on a real operation of a PV plant, showed that the scheme worked effectively within the overall operation range of the PV plant. This paper also discusses the potential of utility factor improvement of the PV-inverter and plant due to implementation of conditioner in the scheme. |
format |
Article |
author |
Jusoh, Awang Hamid, Muhammad Imran |
author_facet |
Jusoh, Awang Hamid, Muhammad Imran |
author_sort |
Jusoh, Awang |
title |
Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
title_short |
Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
title_full |
Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
title_fullStr |
Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
title_full_unstemmed |
Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter |
title_sort |
reduction of waveform distortion in grid-injection current from single-phase utility interactive pv-inverter |
publisher |
Elsevier Ltd. |
publishDate |
2014 |
url |
http://eprints.utm.my/id/eprint/62422/ http://dx.doi.org/10.1016/j.enconman.2014.05.031 |
_version_ |
1643655414550626304 |
score |
13.211869 |