Shake table test of 1:3 scaled HCPS precast concrete wall system

Shake table test is probably one of the most preferred methods in dynamic testing of structures in earthquake engineering. However, due to the constraints imposed by size and payload limitation of the shake table facility, the test models are often smaller than their prototype structures. Although e...

Full description

Saved in:
Bibliographic Details
Main Authors: Adnan, Azlan, Tiong, P. L. Y.
Format: Conference or Workshop Item
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/62118/
http://www.protamuhendislik.com.tr/EN/news/iziis-50-international-conference-on-earthquake-engineering-and-seismology-2015
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.62118
record_format eprints
spelling my.utm.621182017-07-31T06:44:59Z http://eprints.utm.my/id/eprint/62118/ Shake table test of 1:3 scaled HCPS precast concrete wall system Adnan, Azlan Tiong, P. L. Y. QE Geology Shake table test is probably one of the most preferred methods in dynamic testing of structures in earthquake engineering. However, due to the constraints imposed by size and payload limitation of the shake table facility, the test models are often smaller than their prototype structures. Although existing similitude theory allows for proper scaling of test models, it is sometimes impossible to strictly follow every single detail when it comes to practicality in construction of the scaled-down models. This paper investigates the shake table test characteristic of a distorted 1:3, two-storey precast concrete wall structure subjected to eight ground motion records covering both far-and-near field earthquakes. Verified FE models of the test structure were used to compare with the full-scale prototype building using the same group of earthquake records. This study revealed significance agreement between the distorted scaled-down model and prototype building marginal difference below 20 %. 2015 Conference or Workshop Item PeerReviewed Adnan, Azlan and Tiong, P. L. Y. (2015) Shake table test of 1:3 scaled HCPS precast concrete wall system. In: International Conference on Earthquake Engineering and Seismology (IZIIS-50), 12-16 May, 2015, Germany. http://www.protamuhendislik.com.tr/EN/news/iziis-50-international-conference-on-earthquake-engineering-and-seismology-2015
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QE Geology
spellingShingle QE Geology
Adnan, Azlan
Tiong, P. L. Y.
Shake table test of 1:3 scaled HCPS precast concrete wall system
description Shake table test is probably one of the most preferred methods in dynamic testing of structures in earthquake engineering. However, due to the constraints imposed by size and payload limitation of the shake table facility, the test models are often smaller than their prototype structures. Although existing similitude theory allows for proper scaling of test models, it is sometimes impossible to strictly follow every single detail when it comes to practicality in construction of the scaled-down models. This paper investigates the shake table test characteristic of a distorted 1:3, two-storey precast concrete wall structure subjected to eight ground motion records covering both far-and-near field earthquakes. Verified FE models of the test structure were used to compare with the full-scale prototype building using the same group of earthquake records. This study revealed significance agreement between the distorted scaled-down model and prototype building marginal difference below 20 %.
format Conference or Workshop Item
author Adnan, Azlan
Tiong, P. L. Y.
author_facet Adnan, Azlan
Tiong, P. L. Y.
author_sort Adnan, Azlan
title Shake table test of 1:3 scaled HCPS precast concrete wall system
title_short Shake table test of 1:3 scaled HCPS precast concrete wall system
title_full Shake table test of 1:3 scaled HCPS precast concrete wall system
title_fullStr Shake table test of 1:3 scaled HCPS precast concrete wall system
title_full_unstemmed Shake table test of 1:3 scaled HCPS precast concrete wall system
title_sort shake table test of 1:3 scaled hcps precast concrete wall system
publishDate 2015
url http://eprints.utm.my/id/eprint/62118/
http://www.protamuhendislik.com.tr/EN/news/iziis-50-international-conference-on-earthquake-engineering-and-seismology-2015
_version_ 1643655327571247104
score 13.211869