Particulate emission size distribution from palm oil mill boiler

A study on the particulate emission size distribution from five different palm oil mills with boiler steam capacity ranging from 17,000 to 35,000kg/hr was investigated and is reported in this paper. The mills are all equipped with a multi-cyclones particulate arrestor. The particulate sample was col...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamian, Nor Ruwaida, Mohd. Yusof, Mohd. Rashid, Mohd. Muzi, Syahirah
Format: Conference or Workshop Item
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/61234/1/MohdRashidMohd2015_Particulateemissionsizedistributionfrompalmoil.pdf
http://eprints.utm.my/id/eprint/61234/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.61234
record_format eprints
spelling my.utm.612342017-08-13T08:14:59Z http://eprints.utm.my/id/eprint/61234/ Particulate emission size distribution from palm oil mill boiler Jamian, Nor Ruwaida Mohd. Yusof, Mohd. Rashid Mohd. Muzi, Syahirah TP Chemical technology A study on the particulate emission size distribution from five different palm oil mills with boiler steam capacity ranging from 17,000 to 35,000kg/hr was investigated and is reported in this paper. The mills are all equipped with a multi-cyclones particulate arrestor. The particulate sample was collected at the stack (fly ash) and at the multi-cyclone (retained ash). The results showed that the 50% cumulative particulate emission size distribution for stack fly ash ranged between 1.3 and 38 µm and 60 to 150 µm for retained ash. 2015 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/61234/1/MohdRashidMohd2015_Particulateemissionsizedistributionfrompalmoil.pdf Jamian, Nor Ruwaida and Mohd. Yusof, Mohd. Rashid and Mohd. Muzi, Syahirah (2015) Particulate emission size distribution from palm oil mill boiler. In: International Conference on Sustainability Initiatives, 24-25 Aug, 2015, Kuala Lumpur, Malaysia.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Jamian, Nor Ruwaida
Mohd. Yusof, Mohd. Rashid
Mohd. Muzi, Syahirah
Particulate emission size distribution from palm oil mill boiler
description A study on the particulate emission size distribution from five different palm oil mills with boiler steam capacity ranging from 17,000 to 35,000kg/hr was investigated and is reported in this paper. The mills are all equipped with a multi-cyclones particulate arrestor. The particulate sample was collected at the stack (fly ash) and at the multi-cyclone (retained ash). The results showed that the 50% cumulative particulate emission size distribution for stack fly ash ranged between 1.3 and 38 µm and 60 to 150 µm for retained ash.
format Conference or Workshop Item
author Jamian, Nor Ruwaida
Mohd. Yusof, Mohd. Rashid
Mohd. Muzi, Syahirah
author_facet Jamian, Nor Ruwaida
Mohd. Yusof, Mohd. Rashid
Mohd. Muzi, Syahirah
author_sort Jamian, Nor Ruwaida
title Particulate emission size distribution from palm oil mill boiler
title_short Particulate emission size distribution from palm oil mill boiler
title_full Particulate emission size distribution from palm oil mill boiler
title_fullStr Particulate emission size distribution from palm oil mill boiler
title_full_unstemmed Particulate emission size distribution from palm oil mill boiler
title_sort particulate emission size distribution from palm oil mill boiler
publishDate 2015
url http://eprints.utm.my/id/eprint/61234/1/MohdRashidMohd2015_Particulateemissionsizedistributionfrompalmoil.pdf
http://eprints.utm.my/id/eprint/61234/
_version_ 1643655110330417152
score 13.211869